14. Tests
14.7
Local analogue loopback with test pattern
The purpose of this test is to check the receive and transmit circuits
in the local modem. The modem will generate a varying bit-pattern
which will be modulated and demodulated. Numbers of errors will be
counted
and displayed on the screen when the test is ended.
—_—_—__——__»
Preconditions :
Modem
Modulator —_,
The modem must be in command state (Eventually use +++).
Echo must be enabled
(The E1 command ).
Test timer disabled - example 1:
= Enter:
ATS18=0& 18g"),
.|$18=0 disconnects the Test Timer.
he
&T8
Selects Local analogue loopback
with test pattern.
| The lest indicator lights.
AT&TOp*|
me
: The lest will be interrupted.
The modem answers
000
0 fault detected
OK
Test terminated
Alternative 2:
The modem answers
007 7 faults detected
OK
Test terminated
LZTR104006 R1.00
14-7
Zat 14.4/14.4-7 and 19.2/19.2-7