Ericsson ZAT 19.2 Operation Manual page 126

Table of Contents

Advertisement

+819
Bit mapped options
Binary code: xxAx xx00 Default: 50 hex
Bit 1,0 | Not used
0
Bit 2
|Line speed locking
0|(%GO) | Updated by command line
(See %G-command)
prefix AT
1|(%G1) | Updated by the %B command,
or register +S6.
Bit3
|Select &D2 operation |
O|(+&AQ) | Normal &D2 operalion
(See +&A-command) |
1/(+&A1) | Autoanswer with &D2 and
DTR off.
Bit 4 | Trellis coded
0}(+T0)
|Disabled
modulation
1|(+T1)
| Enabled
(See +T -command)
Bil5
{Command mode
Q|(+PNO) | Command mode on
on/off
1|(+PN1) | Command mode off
(See +PN-command)
Bit 7,
|€xtended DCD control | 00}(+U0)
| CD (109) off during lests
6
(See +U-command)
where DTE is not active
01}(+U1)
| CD (109) on during test.
10}(+U2)
|CD (109) always on
11
Not used
+S20
Bit mapped options
Binary code: 0000 Oxxx
Default: 11 hex
Bit 2-0}DSR, CTS control | 000/(&S0)
|DSR and CTS always on
(See &$-command) | 001}(&S1)
|DSR/CTS are controlled
as in standard Hayes.
010)(&S2)
|DSR off and CTS on in
command mode.
DSR and CTS are turned on at
same time as DCD.
011|(&S3)
| DSR off and CTS off
in command mode.
DSR and CTS are turned on at
same time as DCD.
100|(&S4)
{DSR always on,
CTS will never turn on if
RTS is off, but may be switched
off by flow control.
101
Not used
110
Not used
111
Not used
Bit 5-3]
Test pattern for
000 | (+&LTO)|
SPACE pattern
selftest
001 | (+&LT1)!
MARK pattern
(See +&LT-
010|
(+&LT2) | Alternating pallern
command)
011 | (+&LT3) | 511 pattern
1xx
Illegai
746
Not used
4-22
LZTR104006 R1.00
Zat 14.4/14.4-7 and 19.2/19.2-7

Advertisement

Table of Contents
loading

This manual is also suitable for:

Zat 19.2-7Zat 14.4Zat 14.4-7