14.9
Remote digital loopback with test pattern
The purpose of this test is to check the remote modem and the
tetephone line. This is initiated by your own modem sending a
standard test message to the remote modem.
The remote modem loops this test message back to the local
modem, which compares transmitted data with received data and
counts the number of faults
Remote
Modem
Modem
Preconditions:
Your own modem
must have established a connection with the
remote modem
( A-mode or B-mode ).
Echo must be enabled ( E1 command) . The remote modem
must be set to accept request for a Remote Digital Loopback
(&T4 commang ) .
Test timer disconnected - example 1:
=Enter:
o e
| The
modem returns to command state.
$18=0 disables the test timer.
&T7
selects remote digital loopback
= ]
with test pattern.
| Test indicator lights
AT&TO
reall
ce ae
&TO
terminates the test.
The modem answers
7 000
No faults detected
OK
Test terminated
Alternative 2
The modem answers
007
7 faults detected
OK
Test terminated