8XC196MC, MD, MH USER'S MANUAL
XTAL1
XTAL2
NOTE: The CLKOUT pin is unique to the 8XC196MC and MD.
Figure 14-1. Clock Control During Power-saving Modes

14.3 IDLE MODE

In idle mode, the device's power consumption decreases to approximately 40% of normal con-
sumption. Internal logic holds the CPU clocks at logic zero, causing the CPU to stop executing
instructions. Neither the peripheral clocks nor CLKOUT are affected, so the special-function reg-
isters (SFRs) and register RAM retain their data and the peripherals and interrupt system remain
active. Tables in Appendix B list the values of the pins during idle mode (see Table B-8 on page
B-23 for the 8XC196MC and 8XC196MD or Table B-9 on page B-25 for the 8XC196MH).
14-4
Disable Clock Input
(Powerdown)
F
XTAL1
Divide-by-two
Circuit
Clock
Generators
Disable
Oscillator
(Powerdown)
Get other manuals https://www.bkmanuals.com
Disable Clocks
(Powerdown)
Peripheral Clocks (PH1, PH2)
CLKOUT
CPU Clocks (PH1, PH2)
Disable Clocks
(Idle, Powerdown)