COMP x _CON
x = 0–3 (8XC196MC, MH)
x = 0–5 (8XC196MD)
The EPA compare control (COMP x _CON) registers determine the function of the EPA compare
channels.
7
x = 0, 2, 4
TB
7
x = 1, 3, 5
TB
7
TB
6
CE
5:4
M1:0
3
RE
CE
M1
M0
CE
M1
M0
Time Base Select
Specifies the reference timer.
0 = timer 1 is the reference timer and timer 2 is the opposite timer
1 = timer 2 is the reference timer and timer 1 is the opposite timer
A compare event (start of an A/D conversion; clearing, setting, or toggling
an output pin; and/or resetting either timer) occurs when the reference
timer matches the time programmed in the event-time register.
Compare Enable
This bit enables the compare function.
0 = compare function disabled
1 = compare function enabled
EPA Mode Select
Specifies the type of compare event.
M1
M0
0
0
no output
0
1
clear output pin
1
0
set output pin
1
1
toggle output pin
Re-enable
Allows a compare event to continue to execute each time the event-time
register (COMP x _TIME) matches the reference timer rather than only
upon the first time match.
0 = compare function will drive the output only once
1 = compare function always enabled