Z2: Bypass Control Input/Output - YASKAWA P1000 Technical Manual

Ac drive
Hide thumbs Also See for P1000:
Table of Contents

Advertisement

B.14 Z: Bypass Parameters
u

Z2: Bypass Control Input/Output

No.
(Addr.
Name
Hex)
Z2-01
Digital Input 1 Function
(8563)
Select
Z2-02
Digital Input 2 Function
(8564)
Select
Z2-03
Digital Input 3 Function
(8565)
Select
Z2-04
Digital Input 4 Function
(8566)
Select
Z2-05
Digital Input 5 Function
(8567)
Select
Z2-06
Digital Input 6 Function
(8568)
Select
Z2-07
Digital Input 7 Function
(8569)
Select
Z2-08
Digital Input 8 Function
(856A)
Select
Z2-09
(856B)
Digital Input 1 Invert Select
Z2-10
(856C)
Digital Input 2 Invert Select
Z2-11
(856D)
Digital Input 3 Invert Select
Z2-12
(856E)
Digital Input 4 Invert Select
Z2-13
(856F)
Digital Input 5 Invert Select
Z2-14
(8570)
Digital Input 6 Invert Select
Z2-15
(8571)
Digital Input 7 Invert Select
288
0: Unused (Available for Serial Comms)
3: DRV Multi-Function Input S3 (H1-03 Setting)
4: DRV Multi-Function Input S4 (H1-04 Setting)
5: DRV Multi-Function Input S5 (H1-05 Setting)
6: DRV Multi-Function Input S6 (H1-06 Setting)
7: DRV Multi-Function Input S7 (H1-07 Setting)
8: DRV Multi-Function Input S8 (H1-08 Setting)
21: Run (AUTO Mode)
22: Run Enable (Safety)
23: Run Interlock (BAS)
24: Remote Transfer to Bypass
25: Smoke Purge Bypass Run to Destruction
26: Smoke Purge Drive Run to Destruction at Smoke Purge Preset Speed (See
Z1-10). Bypass controller will stay in this state even if the drive faults or is
unavailable.
27: Motor OR Select (2-Motor OR function; 0/1 for Motor 1/2. Behavior
defined by Z1-11)
28: Motor AND Select (2-Motor AND function; 0/1 for 1/2 motor. If 1 motor,
then look to Motor OR input for selected motor. Behavior defined by Z1-11)
29: Motor 1 Overload Contact. When input is open, declare an OL Fault, issue
an EF0 fault to the drive, delay per EF0 Fault Delay Time (Z1-30), and open
Drive Output (K2) and Bypass (K3) contactors.
30: Motor 2 Overload Contact. When input is open, declare an OL Fault, issue
an EF0 fault to the drive, delay per EF0 Fault Delay Time (Z130), and open
Drive Output (K2) and Bypass (K3) contactors.
31: HAND Select
32: AUTO Select
33: DRIVE/BYPASS Select (0/1 for Drive/Bypass)
34: Fault Reset
35: External Fault (EF0)
36: External Fault (EFB)
37: Run Reverse
0: Normal. Lack of input signal = OFF
1: Inverted. Lack of input signal = ON
0: Normal. Lack of input signal = OFF
1: Inverted. Lack of input signal = ON
0: Normal. Lack of input signal = OFF
1: Inverted. Lack of input signal = ON
0: Normal. Lack of input signal = OFF
1: Inverted. Lack of input signal = ON
0: Normal. Lack of input signal = OFF
1: Inverted. Lack of input signal = ON
0: Normal. Lack of input signal = OFF
1: Inverted. Lack of input signal = ON
0: Normal. Lack of input signal = OFF
1: Inverted. Lack of input signal = ON
YASKAWA SIEP YAIP1B 01B YASKAWA AC Drive – P1000 Bypass Technical Manual
Description
<1>
Values
Page
Default: 21
174
Range: 0 to 36
Default: 22
174
Range: 0 to 36
Default: 23
174
Range: 0 to 36
Default: 24
174
Range: 0 to 36
Default: 25
174
Range: 0 to 36
Default: 0
174
Range: 0 to 36
Default: 0
174
Range: 0 to 36
Default: 29
174
Range: 0 to 36
Default: 0
176
Range: 0, 1
Default: 1
176
Range: 0, 1
Default: 0
176
Range: 0, 1
Default: 0
176
Range: 0, 1
Default: 0
176
Range: 0, 1
Default: 0
176
Range: 0, 1
Default: 0
176
Range: 0, 1