Predefined V/f Patterns for Models D030 to D211 and B014 to B096
The voltage values in the graphs for settings 0 to E apply to applications with 200 V motors. Double the voltage values for
400 V motors. The voltage values in settings 0 to E do not apply to 208, 230, or 460 V motor applications.
Setting = 0
50 Hz
200
14
7
0
1.3 2.5
50
Frequency (Hz)
Setting = 4
50 Hz
200
35
6
0
1.3
25
50
Frequency (Hz)
Setting = 8
50 Hz
200
18
9
0
1.3 2.5
50
Frequency (Hz)
Setting = C
90 Hz
200
14
7
0
1.5 3
60
90
Frequency (Hz)
YASKAWA SIEP YAIP1B 01B YASKAWA AC Drive – P1000 Bypass Technical Manual
Table 5.14 Rated Torque Characteristics, Settings 0 to 3
Setting = 1
60 Hz
200
14
7
0
1.5 3
60
Frequency (Hz)
Table 5.15 Variable Torque Characteristics, Settings 4 to 7
Setting = 5
50 Hz
200
50
7
0
1.3
25
50
Frequency (Hz)
Table 5.16 High Starting Torque, Settings 8 to B
Setting = 9
50 Hz
200
23
11
0
1.3 2.5
50
Frequency (Hz)
Table 5.17 Constant Output, Settings C to F
Setting = D
120 Hz
200
14
7
0
1.5 3
60
120
Frequency (Hz)
Setting = 2
60 Hz
200
14
7
0
1.5 3
50
60
Frequency (Hz)
Setting = 6
60 Hz
200
35
6
0
1.5
30
60
Frequency (Hz)
Setting = A
60 Hz
200
18
9
0
1.5 3
60
Frequency (Hz)
Setting = E
180 Hz
200
14
7
0
1.5 3
60
180
Frequency (Hz)
5.5 E: Motor Parameters
Setting = 3
72 Hz
200
14
7
0
1.5 3
60
72
Frequency (Hz)
Setting = 7
60 Hz
200
50
7
0
1.5
30
60
Frequency (Hz)
Setting = B
60 Hz
200
23
13
0
1.5 3
60
Frequency (Hz)
Setting = F
60 Hz
230
16.1
8.1
0
1.5 3
60
Frequency (Hz)