H3: Multi-Function Analog Inputs

No.
(Addr.
Name
Hex)
H3-01
Terminal A1 Signal Level
(410)
Selection
H3-02
Terminal A1 Function
(434)
Selection
H3-03
(411)
Terminal A1 Gain Setting
H3-04
(412)
Terminal A1 Bias Setting
H3-05
Terminal A3 Signal Level
(413)
Selection
H3-06
Terminal A3 Function
(414)
Selection
H3-07
(415)
Terminal A3 Gain Setting
H3-08
(416)
Terminal A3 Bias Setting
H3-09
Terminal A2 Signal Level
(417)
Selection
H3-10
Terminal A2 Function
(418)
Selection
H3-11
(419)
Terminal A2 Gain Setting
H3-12
(41A)
Terminal A2 Bias Setting
H3-13
A1/A2 Input Filter Time
(41B)
Constant
H3-14
Analog Input Terminal
(41C)
Enable Selection
H3-16
Terminal A1 Offset
(2F0)
YASKAWA SIEP YAIP1B 01B YASKAWA AC Drive – P1000 Bypass Technical Manual
Description
0: 0 to 10 V with zero limit
1: 0 to 10 V without zero limit
2: 4 to 20 mA
3: 0 to 20 mA
Note:
Use jumper switch S1 to set input terminal A1 for current or
voltage.
Sets the function of terminal A1.
Sets the level of the input value selected in H3-02 when 10 V is input at
terminal A1.
Sets the level of the input value selected in H3-02 when 0 V is input at terminal
A1.
0: 0 to 10 V with zero limit
1: 0 to 10 V without zero limit
2: 4 to 20 mA
3: 0 to 20 mA
Note:
Use Jumper S1 to set input terminal A3 for a current or voltage
input signal.
Sets the function of terminal A3.
Sets the level of the input value selected in H3-06 when 10 V is input at
terminal A3.
Sets the level of the input value selected in H3-06 when 0 V is input at terminal
A3.
0: 0 to 10 V with zero limit
1: 0 to 10 V without zero limit
2: 4 to 20 mA
3: 0 to 20 mA
Note:
Use jumper switch S1 to set input terminal A2 for current or
voltage input signal.
Sets the function of terminal A2.
Sets the level of the input value selected in H3-10 when 10 V (20 mA) is input
at terminal A2.
Sets the level of the input value selected in H3-10 when 0 V (0 or 4 mA) is
input at terminal A2.
Sets a primary delay filter time constant for terminals A1 and A2. Used for
noise filtering.
Determines which analog input terminals will be enabled when a digital input
programmed for "Analog input enable" (H1-oo = C) is activated.
1: Terminal A1 only
2: Terminal A2 only
3: Terminals A1 and A2 only
4: Terminal A3 only
5: Terminals A1 and A3
6: Terminals A2 and A3
7: All terminals enabled
Adds an offset when the analog signal to terminal A1 is at 0 V.
B.8 H Parameters: Multi-Function Terminals
Values
Page
Default: 0
124
Range: 0 to 3
Default: 0
125
Range: 0 to 26
Default: 100.0%
Min.: -999.9
125
Max.: 999.9
Default: 0.0%
Min.: -999.9
125
Max.: 999.9
Default: 0
127
Range: 0 to 3
Default: 2
127
Range: 0 to 26
Default: 100.0%
Min.: -999.9
127
Max.: 999.9
Default: 0.0%
Min.: -999.9
127
Max.: 999.9
Default: 2
127
Range: 0 to 3
Default: 0
127
Range: 0 to 26
Default: 100.0%
Min.: -999.9
128
Max.: 999.9
Default: 0.0%
Min.: -999.9
128
Max.: 999.9
Default: 0.03 s
Min.: 0.00
128
Max.: 2.00
Default: 7
128
Range: 1 to 7
Default: 0
Min.: -500
129
Max.: 500
263