D.9 MEMOBUS/Modbus Data Table
Register No.
0099H
Low Word of Accumulated Operation Time Monitor, 1 h units (U4-01)
009AH
High Word of Cooling Fan Operation Time Monitor (U4-03)
009BH
Low Word of Cooling Fan Operation Time Monitor (U4-03)
009CH to 00AAH
Reserved
00ABH
Drive Rated Current
Motor Speed (U1-05)
00ACH
Note: Not available in
00ADH
P1000.
00AEH to 00B4H
Reserved
00B5H
Frequency Reference After
Soft-starter (U1-16)
00B6H
00B7H
Frequency Reference
00B8H
00B9H to 00BEH
Reserved
00BFH
Lists the last two digits of operation error code oPEoo.
Fault Contents 3
bit 1
bit 2
bit 3
bit 4
bit 5
bit 6
00C0H
bit 7
bit 8
bit 9
bit A
bit B
bit C
bit D to F
Fault Contents 4
bit 0
bit 1
bit 2
bit 3
bit 4
bit 5
00C1H
bit 6
bit 7 to 9
bit A
bit B
bit C
bit D
bit E
bit F
342
<2>
<4>
r/min units
0.01% units
<4>
r/min units
0.01% units
<4>
r/min
0.01% units
Undervoltage (Uv1)
Control Power Supply Undervoltage (Uv2)
Soft Charge Circuit Fault (Uv3)
Reserved
Ground Fault (GF)
Overcurrent (oC)
Overvoltage (ov)
Heatsink Overheat (oH)
Heatsink Overheat (oH1)
Motor Overload (oL1)
Drive Overload (oL2)
Overtorque Detection 1 (oL3)
Reserved
External Fault at input terminal S3 (EF3)
External Fault at input terminal S4 (EF4)
External Fault at input terminal S5 (EF5)
External Fault at input terminal S6 (EF6)
External Fault at input terminal S7 (EF7)
Reserved
Cooling Fan Error (FAn)
Reserved
Input Phase Loss (PF)
Output Phase Loss (LF)
Motor Overheat (PTC input) (oH3)
Digital Operator Connection Fault (oPr)
EEPROM Write Error (Err)
Motor Overheat Fault (PTC input) (oH4)