Register No.
Output Terminal Status
bit 0
bit 1
002DH
bit 2
bit 3 to 6
bit 7
bit 8 to F
002EH
Reserved
002FH
Frequency Reference Bias (from Up/Down 2 Function), 0.1% units
0030H
Reserved
0031H
DC Bus Voltage, 1 Vdc units
0032H, 0033H
Reserved
0034H
Product Code 1 [ASCII], Product Type
0035H
Product Code 2 [ASCII], Region Code
0036H, 0037H
Reserved
0038H
PI Feedback, 0.1% units, unsigned, 100% / max. output frequency
0039H
PI Input, 0.1% units, signed, 100% / max. output frequency
003AH
PI Output, 0.1% units, signed, 100% / max. output frequency
003BH, 003CH
Reserved
Communications Error Contents
bit 0
bit 1
bit 2
003DH
bit 3
bit 4
bit 5
bit 6
bit 7 to F
003EH
Output Frequency
003FH
0040H to 004AH
Used for various monitors U1-oo.
Drive status (U1-12)
bit 0
bit 1
bit 2
bit 3
bit 4
bit 5
004BH
bit 6
bit 7
bit 8
bit 9
bit A, bit B
bit E
bit F
004CH to 007EH
Used for various monitors U1-oo, U4-oo, U5-oo and U6-oo.
007FH
Alarm Code,
Used for monitors U2-oo, U3-oo.
0080H to 0097H
Contents on page 348
0098H
High Word of Accumulated Operation Time Monitor, 10 h units (U4-01)
YASKAWA SIEP YAIP1B 01B YASKAWA AC Drive – P1000 Bypass Technical Manual
Multi-Function Contact Output 1 (terminal MD-ME-MF)
Multi-Function Contact Output 2 (terminal M1-M2)
Multi-Function Contact Output 3 (terminal M3-M4)
Reserved
Fault Contact Output (terminal MA/MB-MC)
Reserved
<2>
CRC Error
Data Length Error
Reserved
Parity Error
Overrun Error
Framing Error
Timeout
Reserved
<4>
r/min
0.01% units
Refer to U: Monitors on page 275
During Run
During Zero Speed
During Reverse Run
During Fault Reset Signal Input
During Speed Agree
Drive Ready
Alarm
Fault
During Operation Error (oPEoo)
During Momentary Power Loss
Reserved
ComRef status, NetRef status
ComCtrl status, NetCtrl status
Refer to Alarm Register Contents on page 350
Refer to U: Monitors on page 275