Motor Type
Stationary Auto-Tuning for Line-to-Line Resistance
Induction
Motor
Rotational Auto-Tuning for V/f Control
n
Notes on Stationary Auto-Tuning
Stationary Auto-Tuning modes analyze motor characteristics by injecting current into the motor for approximately one minute.
WARNING! Electrical Shock Hazard. When executing stationary Auto-Tuning, voltage is applied to the motor before the motor rotates. Do
not touch the motor until Auto-Tuning is completed. Failure to comply may result in injury or death from electrical shock.
WARNING! Sudden Movement Hazard. If installed, do not release the mechanical brake during Stationary Auto-Tuning. Inadvertent brake
release may cause damage to equipment or injury to personnel. Ensure that the mechanical brake release circuit is not controlled by the
drive multi-function digital outputs.
Stationary Auto-Tuning for Line-to-Line Resistance
• Perform when entering motor data manually while using motor cables longer than 50 m.
• If the motor cables have been replaced with cables more than 50 m long after Auto-Tuning has already been performed, use
Stationary Auto-Tuning for line-to-line resistance.
u

Auto-Tuning Interruption and Fault Codes

If tuning results are abnormal or the OFF key is pressed before completion, Auto-Tuning will be interrupted and a fault code
will appear on the HOA keypad.
A – During Auto-Tuning
u

Auto-Tuning Operation Example

The following example demonstrates Rotational Auto-Tuning for V/f.
n
Selecting the Type of Auto-Tuning
1.
Turn on the power to the drive. The initial display appears.
2.
Press
or
until the Auto-Tuning display appears.
3.
Press
to begin setting parameters.
4.
Press
to display the value for T1-01.
YASKAWA SIEP YAIP1B 01B YASKAWA AC Drive – P1000 Bypass Technical Manual
Table 4.8 Auto-Tuning Input Data
Auto-Tuning Type
A
DIGITAL OPERATOR JVOP-180
ALM
DRV-OFF
Tune Proceeding
X.XX Hz/ X.XXA
<
<<
<<<
>>
>>>
>
LO
ESC
RE
Figure 4.11 Auto-Tuning Aborted Display
RESET
ENTER
RUN
STOP
Step
Digital Input
Maintains the status at the start of Auto-Tuning
Digital input functions
are disabled.
Functions the same as during normal operation
B
ALM
DIGITAL OPERATOR JVOP-180
DRV-OFF
Er-03
STOP key
RESET
B – Auto-Tuning Aborted
LO
ESC
RE
RESET
ENTER
RUN
STOP
4.7 Auto-Tuning
Digital Output
Display/Result
DRV-OFF
Freq Ref (AUTO)
U1-01= 60.00Hz
U1-02= 0.00Hz
LSEQ
U1-03= 0.00 A
LREF
RLY
DRV/BYP
DRV-OFF
Auto-Tuning
Auto
HELP
DATA
DRV-OFF
Tuning Mode Sel
T1-01= 2
*2*
Line-to-Line
ESC
DATA
DRV-OFF
Tuning Mode Sel
T1-01=
2
*2*
Line-to-Line
"0"
ESC
DATA
77