Device Object - YASKAWA P1000 Technical Manual

Ac drive
Hide thumbs Also See for P1000:
Table of Contents

Advertisement

Object ID
BV66
BV67
BV68
BV69
BV70
BV71
<2>
BV72
<2>
BV73
<2>
BV74
<2>
BV75
<2>
BV76
<2>
BV77
<2>
BV78
<2>
BV79
BV80
BV81
BV82
BV83
BV84
BV85
BV86
BV87
BV88
BV89
BV90
BV91
BV92
BV93
BV94
BV95
BV96
BV97
BV98
BV99
BV100
BV101
BV102
BV103
BV104
BV105
BV106
BV107
<1>
Refer to Accessing Bypass Parameters and the Enter Command on page 321
listed in the analog or binary objects.
<2> Object is disabled when Z3-12 is set to 0 in bypass controller software versions VST800298 and later.
u

Device Object

The Device Object fully describes the BACnet device to the network. Notable is that the Device Object Instance ID and the
Device Object Name are configurable.
YASKAWA SIEP YAIP1B 01B YASKAWA AC Drive – P1000 Bypass Technical Manual
Object Name
BYP Drive Select CMD
BYP Auto Select CMD
Not Used BV68
BYP BYPASS Sel CMD
BYP Fault Reset CMD
BYP Ext Fault CMD
BYP DI-01 Command
BYP DI-02 Command
BYP DI-03 Command
BYP DI-04 Command
BYP DI-05 Command
BYP DI-06 Command
BYP DI-07 Command
BYP DI-08 Command
BYP HAND Mode Status
BYP OFF Mode Status
BYP AUTO Mode Status
BYP DRV Mode Status
BYP BYPASS Mode Stat
BYP Smk Prg BYP Stat
BYP Smk Prg DRV Stat
BYP Safety Status
BYP BAS Interlk Stat
BYP RUN Status
BYP Fault Status
BYP Auto Xfer Status
BYP Remote Xfer Stat
BYP Energy Save Stat
BYP Motor 1 Sel Stat
BYP Motor 2 Sel Stat
BYP Drive Flt Status
BYP Safety Flt Stat
BYP BAS ILock Status
BYP Ext Fault Stat
Not Used BV100
BYP Motor OL Stat
BYP Motor 1 OL Stat
BYP Mtr 2 OL Stat
BYP Input Phase Loss
BYP Drive Comms
BYP Loss Of Load
BYP Option Brd Comms
Modbus
Active Text
Address
8400H: bit 9
ON
8400H: bit 10
ON
8400H: bit 11
ON
8400H: bit 12
BYP
8400H: bit 13
ON
8400H: bit 14
ON
8402H: bit 0
ON
8402H: bit 1
ON
8402H: bit 2
ON
8402H: bit 3
ON
8402H: bit 4
ON
8402H: bit 5
ON
8402H: bit 6
ON
8402H: bit 7
ON
8784H: bit 0
ON
8784H: bit 1
ON
8784H: bit 2
ON
8784H: bit 3
ON
8784H: bit 4
ON
8784H: bit 5
ACTIVE
8784H: bit 6
ACTIVE
8784H: bit 7
OPEN
8785H: bit 0
OPEN
8785H: bit 1
RUN
8785H: bit 2
FAULT
8785H: bit 3
ACTIVE
8785H: bit 4
ACTIVE
8785H: bit 5
ACTIVE
8785H: bit 6
SELECT
8785H: bit 7
SELECT
8786H: bit 0
FAULT
8786H: bit 1
FAULT
8786H: bit 2
FAULT
8786H: bit 3
FAULT
8786H: bit 4
FAULT
8786H: bit 5
FAULT
8786H: bit 6
FAULT
8786H: bit 7
FAULT
8787H: bit 0
FAULT
8787H: bit 2
FAULT
8787H: bit 5
FAULT
8787H: bit 3
FAULT
for an explanation of how to read and write drive parameters not
C.6 BACnet Objects Supported
Inactive Text
PV Access
OFF
OFF
OFF
DRV
OFF
OFF
OFF
OFF
OFF
OFF
OFF
OFF
OFF
OFF
OFF
OFF
OFF
OFF
OFF
OFF
OFF
CLOSED
CLOSED
OFF
OFF
OFF
OFF
OFF
OFF
OFF
OFF
OFF
OFF
OFF
OFF
OFF
OFF
OFF
OFF
OFF
OFF
OFF
C
C
C
C
C
C
W
W
W
W
W
W
W
W
R
R
R
R
R
R
R
R
R
R
R
R
R
R
R
R
R
R
R
R
R
R
R
R
R
R
C
R
R
319