E010 Main Motor Fails To Lock; E030 The Total Counter Fails; E031 The Fax Counter Fails - Oce 3121 Technical & Service Manual

Table of Contents

Advertisement

6 E010 Main motor fails to lock

Cause
Main motor
(including motor
driver PBA)
DC power supply
Main motor
DC control PBA

7 E030 The total counter fails.

Cause
DC control PBA

8 E031 The fax counter fails.

Cause
DC control PBA
ed.2
Step Checks
1
Does the main motor
rotate until 'E010' is
indicated?
2
Is MLCK 0 V (main
motor specific speed sig-
nal), while the main
motor is running?
3
Is the voltage between
the following connectors
on the main motor driver
normal? J150-1: 24 V
J150 2 = 0 V.
4
Replace the main motor.
Is the problem corrected?
Step Checks
1
Check the operation of
the counters.
Counter 1 (right): total
copy counter
Counter 2 (centre):
printer counter
Step Checks
1
Check the operation of
the fax counter.
Counter 3 (left): fax
counter
Yes/No
Action
No
Go to step 4.
No
Replace the main motor.
No
Check the wiring from
J204-3 (24 V)/J204-4 (0
V) on the composite
power supply PBA to the
main motor; if normal,
see "DC power is
absent."
Yes
End.
No
Replace the DC control
PBA
Yes/No
Action
No
See "The counter fails
to operate."
Yes
Replace the DC control
PBA
Yes/No
Action
No
"The counter fails to
operate."
Replace the DC control
Yes
PBA PBA
Trouble shooting 17

Advertisement

Table of Contents
loading

This manual is also suitable for:

3122

Table of Contents