##285 (recep) DCN has been received, after transmitting EOP during transmission.
Main cause
Stop has been pressed during communica-
I
tion.
##286 (trans) DCN has been received, after transmitting EOM during transmission.
Main cause
Stop has been pressed during communica-
I
tion.
##287 (trans) DCN has been received, after transmitting MPS during transmission.
Main cause
Stop has been pressed during communica-
I
tion.
##288 (trans) A signal, other than PIN, RIP, MCF, RTP, or RTN, has been received
during transmission.
Main cause
There is an error in the protocol signal.
I
##289 (trans) A signal, other than PIN, RIP, MCF, RTP, or RTN, has been received
after transmission of EOM.
Main cause
There is an error in the protocol signal.
I
##290 (trans) A signal, other than PIN, RIP, MCF, RTP, or RTN, has been received
after transmitting MPS during transmission.
Main cause
There is an error in the protocol signal.
I
66
TSM Océ 3121/3122
Action
Try transmission once again.
I
Action
Try transmission once again.
I
Action
Try transmission once again.
I
Action
Record the communication procedure
I
sound on DAT, for analysis by a technical
centre.
Action
Record the communication procedure on
I
DAT, for analysis by a technical centre.
Action
Record the communication procedure on
I
DAT, for analysis by a technical centre.