* A jam code is a 4-digit code, the high-order 2 digits indicating the type of
I
jam and the low-order 2 digits, the sensor which detected the jam. Set the ta-
ble below for level 1 classification of the jam codes.
Jam code
High-order 2 digits
01:delay
02:stationary
10:residual (at power-on)
11:door open
00:multi tray 12/feeder
8
TSM Océ 3121
01 0821 1430 1435 0
time of recovery (14:35)
time of occurrence (14:30)
date of occurrence (August 21)
No.
FF
Low-order 2 digits
01:pre-registration sensor (PS5)
02:vertical path sensor (PS8)
03:vertical path sensor (pedestal; Q1603)
32:fixing delivery sensor (PS7)
33:delivery sensor (PS13)
34:delivery tray 2 paper sensor (multi tray 3; PS17)
35:delivery tray 3 paper sensor (multi tray 3; PS 18)
61:Multi tray 3 inlet sensor (PS19)
62:Duplexing unit inlet sensor (PS12)
63:re-pick up paper sensor (PS11)
01:front door
02:right door
03:pedestal right door
See p. 7-51.
0101 1
06543 000A4
soft counter reading
of the source of paper
1st cassette
jam code (pre-registration delay
jam)
location
A4 paper jam
SDS Description