Item
ADJ-S
LASER-OFF
PWM 600 MIN
PWM 600 MAX
PWM 200 MIN
PWM 200 MAX
ed.1
Description
Use it to fine-adjust the point at which
data for shading correction is measured
on the standard white plate.
The adjustment is in units of 1/12
I
mm.
The presence of scratches on the
I
standard white plate can cause notice-
able white, vertical lines on copies. If
such is the case, shift the point of
measurement in ADJ-S
Use it to adjust the laser OFF timing
(trailing edge).
Use it to enter laser basic values
Label on the image processor PBA:
P6L: Value for PWM600MIN
P6M: Value for PWM600MAX
P2M: Value for PWM200MIN
P2L: Value for PWM200MAX
Settings Remarks
50~80
0~65535
0~65535
If you have initial-
ized the RAM or
replaced the image
processor PBA,
enter the value
recorded on the
label attached to
the image proces-
sor PBA.
SDS Description 41