Code
Main cause
E202
The scanner home position cannot be
detected.
No code
I
Scanner home sensor PS1
I
indica-
Scanner motor M2
I
tion.
DC control PBA
I
Keys on
I
control
panel
locked.
E220
Scanning lamp (error activation)
I
Scanning lamp
I
Composite power supply PBA
I
DC control PBA
I
E240
An error in the communication with
the DC control PBA has occurred.
DC control PBA
I
Image processor PBA
I
E243
An error has occurred in communica-
tion with the control panel.
Control panel CPU
I
Image processor PBA
I
E261
There is an error in the zero cross sig-
nal.
Power supply frequency (fluctua-
I
tion)
Composite power supply PBA
I
E301
The intensity of the scanning lamp is
incorrectly adjusted.
Intensity sensor
I
Scanning lamp
I
DC control PBA
I
E400
Fault in data communication with
I
(RDF)
copier
E401
Pick-up motor M1: fails to rotate
I
(RDF)
Pick-up roller sensor S5
I
ed.2
Description
The scanner does not return to home
I
position after it has started to move.
Activation of the lamp has been de-
I
tected during stand-by.
Deactivation of the lamp has been de-
I
tected during copying.
An error has been detected in the
I
communication between the DC con-
trol PBA an the image processing
PBA.
An error has been detected in the com-
munication between the CPU on the
control panel and the image processor
PBA.
The intervals of zero cross signals are
outside the allowed range.
The communication is monitored at
I
all times. This error is identified when
the communication with the copier is
interrupted for 5 sec or more.
A vane is fitted to the shaft of the
I
pick-up motor M1. The rotation is
monitored by checking the passage of
the vane past the sensor S5. This error
is identified if S5 is not switched on
and off twice within 1 sec.