The Scanner Fails To Move Forward Or In Reverse; The Pre-Exposure Lamp Fails To Switch On - Oce 3121 Technical & Service Manual

Table of Contents

Advertisement

51 The scanner fails to move forward or in reverse.

Cause
Step
Scanner cable 1
The scanner
2
path is dirty.
Connector
3
(poor con-
tact)
Scanner
4
motor M2
DC control
PBA

52 The pre-exposure lamp fails to switch ON.

Cause
Step
1
Pre-exposure
lamp
DC control
PBA
44
TSM Océ 3121/3122
Checks
Is the scanner drive cable
positioned correctly?
Inspect the scanner rail for
dirt or obstructions. Check
that the scanner moves
smoothly.
Check the wiring/connection
from the connector J116 on
the DC controller PBA to the
scanner motor. Is it normal?
Replace the scanner motor. Is
the problem solved?
Checks
Connect the + to J107-A11
and the – to J107-A12 on the
DC control PBA. Does the
meter reading change from
0V to approximately 24 V
when the copy button is
pressed?
Yes/No Action
No
Reposition the cable.
No
Check the surface of the
scanner rail for foreign
matter or an object that
comes into contact with
the scanner.
No
Correct it.
Yes
End .
No
Replace the DC control
PBA
Yes/No Action
Yes
Check the wiring from
the DC controller PBA
to the pre-exposure
lamp; if normal, replace
the pre-exposure lamp.
No
Replace the DC control
PBA
Error code solving / machine fault solving

Advertisement

Table of Contents
loading

This manual is also suitable for:

3122

Table of Contents