Programming From The Control Panel; Programming Via Keypad - INIM Electronics Prime Programming Manual

Anti-intrusion control panels and security systems
Table of Contents

Advertisement

Programming manual

Programming from the Control panel

The Prime system has been especially designed to be programmed either from a keypad
(using one of the keypads connected to the control panel) or from a PC via Prime/STUDIO
software.
All the options, functions and parameters of the Prime control panel must be programmed by
qualified persons only.
The control panels are programmed at the factory with almost ready-to-go settings ("default
settings") which require only minor changes during the system customization phase. For
example, all the zones, keypads and readers are assigned to (belong to) partition 1, alarm and
tamper events related to partition 1 activate the relay output which is monostable set at 3
minutes (Monostable time = 3 minutes), etc.
All the parameters and programming data can be set via keypad or PC (equipped with the
Prime/STUDIO software) with the following limitations.
• From the keypad you cannot program:
•• timer exceptions
•• input calibration
•• BUS speed
•• description of Emergency keys
•• Ethernet communication parameters
•• PrimeLAN board parameters
•• GPRS, GSM and 3G communication parameters
•• Nexus communicator parameters
•• sounder/flasher tone
•• I-BUS Ivy-B parameters
•• Air2-Hedera wireless sounder/flasher parameters
•• programmable events
•• shortcut on event
•• output scenarios
•• configuration of cameras
•• configuration of graphic maps
• via the Prime/STUDIO software you cannot program:
•• DTMF sensitivity
•• the second Installer code
•• the installer code PINs
•• the shortcut descriptions
•• Air2-BS200 transceiver channel
•• calibration of the temperature read by the keypad thermometer

Programming via keypad

The programming of the control panel via one of the Prime system keypads can be carried out
only after a valid access to the installer menu.
If you wish to program the system via the installer menu from a keypad and thus read/write
the control panel parameters, you must:
1. Disarm all the control panel partitions.
2. Type-in the installer code Pin on a keypad then press OK.
If you are working on an Alien keypad, you must first access the "Settings" section ,
type in the user code and access the "Installer section" then enter the Installer code.