Chapter 12 Programming Events - INIM Electronics Prime Programming Manual

Anti-intrusion control panels and security systems
Table of Contents

Advertisement

12
Chapter
Note
Via software
Via keypad
56
Programming events
The programming of events includes the programming of actions that the control panel must
carry out at the occurrence of events. The control panel recognizes all of the events described
in this paragraph and, in accordance with programming, is capable of generating pre-
programmed actions for each event, both when the event occurs and when it restores/ends.
The actions are:
• activation of outputs
• activation/deactivation of outputs
• event notification via telephone call
• send SMS text messages
• event storage
• management of voice messages
• management of the option of each event
• activation of event related shortcuts
Telephone notifications (calls) are queued and sent out in chronological order. However, some
events may need to be notified immediately (for example, use of a code under duress),
therefore, such events can be given priority by selecting the "Priority" option.
Event notification via e-mail requires the use of a PrimeLAN board (refer to Chapter 13
Programming the PrimeLAN board).
Event notification via predefined SMS messages requires the use of a Nexus (refer to
paragraph 3-5-3 SMS message texts).
If a list of telephone calls is programmed for the notification of an event as well as SMS messages, the
SMS messages will be sent before the telephone calls.
The following table shows the events the control panel recognizes (described in the Appendix
F, Event type), the number of events for each type, the activation and restoral modes of each
event and if the event is a pulse type event.
Click-on the Events button on the menu on the left, the "Programming" section accesses
various sections.
• Events list, this section is where all the available events and their parameters are listed.
The programming field above "Event type" performs a filter on the display of events, in
accordance with the type.
Selecting one of these items allows you to set the parameters of the single event by
clicking on the
button.
• Event maintenance, this section groups together all the fast programming functions of
the events.
• Configure other outputs, this section allows you to configure the set of outputs
selectable for each individual event in the Other outputs section.
• Output scenarios, this section allows you program the scenarios of the outputs that are
to be associated with activation and restoral of each event.
Type-in Code (Installer PIN) , PROGRAMMING Events
This section allows you to program the various options of each selected event.
1. Using the
and
2. Using the
and
type and press OK.
3. Select:
-
Activation, to program the actions to be carried out when the event occurs.
-
Restoral, to program the actions to be carried out when the event ends.
4. Set the parameters relating to the event activation or restoral actions.
buttons select the event type and press OK.
buttons select the single event from the previously selected
Centrali anti-intrusione
Programming events

Advertisement

Table of Contents
loading