INIM Electronics Prime Programming Manual page 79

Anti-intrusion control panels and security systems
Table of Contents

Advertisement

Programming manual
Reader LED OFF
Hide status
Hide icons
Alarm delay
Fault memory LED
Reader Buzzers OFF
Bypass tamper in the event
of bypassed zones
Zone fuse fault
I-BUS fuse fault
Low battery
Mains failure
Telephone line down
Jamming
Low battery wireless
Wireless zone loss
Loss or tamper ongoing
Requires code
Clear call queue on disarm
Zones configured as "24H", "Automation" are non-compliant.
Zones programmed as "Arm", "Disarm", "Switch" or "Follow" comply only when activated by
keyswitches with more than 10,000 code combinations.
An input is set up for system fault management.
For zones with the "Fault zone" option enabled, it is necessary to eliminate from the relative
alarm event the programming of an external sounder/flasher in the "Outputs" parameter. You
can programme indoor sounderflashers via the "Other outputs" option.
The system must include a self-powered outdoor sounder/flasher for intrusion-alarm event
signalling.
The telephone dialer must be enabled.
If you use a digital dialer or voice dialer with SmartLogos30M board for transmissions, a
telephone number must be reserved for the following events:
• All events generated by zones with the "Hold-up" attribute.
• All events generated by "Instant", "Delayed", "Delayed unhidden" and "Route"
• All events generated by terminal, peripheral and control panel tamper.
• All faults detected by the control panel.
The "Alarm Cycles" parameter of each zone must be set between 3 and 10.
The "Mains fail.Delay" parameter must be set at no more than 1 minute.
The "Entry Time" of each partition must be set at a maximum of 45 seconds.
You must enable the "Priority" option for any alarm events associated with "Hold-up" zones.
"Failed to arm" and "Forced arming" events must be saved to the Events log.
Compliance with rules in force
Table 19-1: EN50131 grade 2 - Enablement of options
Table 4-6: Parameters for
compliance
Table 3-4: Parameters
common to all readers
Table 4-3: Control panel
options
Table 4-6: Parameters for
compliance
Table 3-2: Parameters for
single keypads
Table 5-1: Parameters for
single partitions
Regulatory
compatibility,
Parameters
50131
Reader parameters
Control panel
parameters
Regulatory
Other parameters,
compatibility
FaultForNotReady
Forced arming
faults
Configured keypads ,
Shortcut Func.keys,
selected keypad,
"Fx", Options, Re-
General, Advanced
quires code
Partitions,
Partitions, "parti-
selected partition
tion", StopTelOn Dis-
arm
Enabled
50131ReaderLedOFF
Enabled
50131StatHidden
Enabled
50131IconsHidden
Enabled
50131AlarDelayed
Enabled
50131WarnLedMem
Disabled
ReaderBuzzer OFF
Disabled
BypassAlsoTamper
Enabled
Zone fuse fault
Enabled
IBUS fuse fault
Enabled
Low battery
Enabled
Mains failure
Enabled
Tel. line down
Enabled
Jamming
Enabled
Low battery WLS
Enabled
WLS zone loss
Enabled
LossTamp.ongoing
Enabled
Disabled
ZONES
SOUNDER/
FLASHERS
TELEPHONE
DIALER/
COMMUNICATOR
PARAMETERS
79