INIM Electronics Prime Programming Manual page 104

Anti-intrusion control panels and security systems
Table of Contents

Advertisement

Name
Valid code at keypad
Valid Code AtKeyp.
Valid key at reader
ValidKeyAtReader
Valid user-code on
Partition code
partition
Valid key on partition
Partition key
Failed call
Failed call
Timer activated
Timer activated
Thermostat on keypad
Thermostat ON
Activate scenario
Scenario ON
Programmable event
ProgrammableEvt
Emergency button
Emergency button
Panic
Panic Panic
Periodic event
Periodic event
Open-panel tamper
Control panel open
Dislodged-panel tam-
Dislodged panel
per
Zone fuse fault
Zone fuse fault
I-BUS fuse fault
IBUS fuse fault
Battery fault
Low battery
Mains failure
Mains failure
Expansion tamper
Expansion tamper
Keypad Tamper
Keypad tamper
Reader Tamper
Reader tamper
Sounder flasher tam-
Sound.flash.Tamp
per
Nexus tamper
Nexus tamper
LIVPWR100 tamper
Tamp. LIVPWR100
Video detector tamper
VideoSens.Tamper
I/O expansion loss
Expansion loss
Keypad Loss
Keypad loss
Reader Loss
Reader loss
Sounder/flasher loss
Sound.flash.Loss
Nexus loss
Nexus loss
LIVPWR100 loss
Nexus LIVPWR100
Video detector loss
VideoSensor loss
Jamming
Jamming
Low battery on wire-
Low battery WLS
less zone
Wireless zone loss
WLS zone loss
Valid Installer code
Installer code
Invalid code
Invalid code
False key
False key
Nexus fault
Nexus fault
Telephone line down
Tel. line down
Hard reset
Hard reset
Call queue full
Call queue full
104
Occurs when...
An entered user-code PIN is recognized
as valid on the keypad
A key used at a reader is recognized as
valid on the reader
An entered user-code PIN is recognized
as valid on the partition
A key used at a reader is recognized as
valid on the partition
All attempts to call a specific telephone
number have failed
The timer is enabled (On)
The activation conditions set for the key-
pad thermostat occur.
The status of all the partitions corre-
sponds exactly to the pre-set scenario.
See paragraph 12-5 Programmable events
One of the emergency-buttons is pressed
The "Panic" shortcut has been activated.
The Periodic Event occurs
The control-panel enclosure is removed
The control-panel enclosure is detached
from the wall
The zone protection fuse on the control
panel is not operational (blown)
The I-BUS protection fuse is not opera-
tional (blown)
The backup battery is low
(voltage below 10.4V)
The primary power supply 230V~ fails
An expansion board signals tamper condi-
tions
A keypad signals tamper conditions
A reader signals tamper conditions
Tamper conditions on a sounder/flasher
on the BUS
The GSM dialer Nexus signals tamper
An expansion board cannot be found on
the BUS
A keypad cannot be found on the BUS
A reader cannot be found on the BUS
A sounder/flasher cannot be found on the
BUS
The control panel is unable to communi-
cate the Nexus 100
Wireless interference detected
The battery of a least one wireless detec-
tor is running low
Loss of at least one wireless detector has
been signalled (supervisory time expired)
An Installer PIN entered at a keypad is
recognized as valid
An invalid code PIN is entered at a key-
pad
An invalid key is used at a reader
The Nexus device signals a fault (refer to
the <User manual)
The land line is not working
The control panel re-initializes. The sys-
tem clock may be wrong or not working
properly.
There are no more slots left in the outgo-
ing call queue
Restores when ...
One call to the phone number has
been successful
The timer is disabled (Off)
The deactivation conditions set
for the keypad thermostat occur.
The status of all least one of the
partitions does not correspond to
the pre-set scenario.
The front of the control-panel is
replaced
The control-panel enclosure is
reattached to the wall
The zone protection fuse on the
control panel restores
The I-BUS protection fuse
restores
The backup battery is charged
(voltage above 11.4V)
The primary power supply 230V~
is restored
Tamper conditions clear on all the
system expansion boards
Tamper conditions clear on all the
system keypads
Tamper conditions clear on all the
system readers
All the sounder/flashers on the
BUS reset
Tamper conditions clear on the
Nexus
For future use
For future use
All expansion boards can be
found on the BUS
All keypads can be found on the
BUS
All readers can be found on the
BUS
All sounder/flashers can be found
on the BUS
Communication between the con-
trol panel and the Nexus restores
For future use
For future use
Wireless interference cleared
All the wireless detectors are run-
ning with sufficient power
All the wireless detector are pres-
ent
Fault conditions clear on the
Nexus
The land line restores
Centrali anti-intrusione
Pulse
Number of events
events
One event for each
Yes
keypad
One event for each
Yes
reader
One event for each
Yes
partition
One event for each
Yes
partition
One event for each
contact telephone
no
number
One event for each
no
timer
One event for each
no
keypad
One event for each
no
scenario
no
One event for each
Yes
emergency-button
15
Yes
4
Yes
1
no
1
no
1
no
1
no
1
no
1
no
1
no
1
no
1
no
1
no
1
no
1
no
1
no
1
no
1
no
1
no
1
no
1
no
1
no
1
Yes
1
Yes
1
Yes
1
no
1
no
1
Yes
1
Yes
Event type