INIM Electronics Prime Programming Manual page 26

Anti-intrusion control panels and security systems
Table of Contents

Advertisement

If enabled, this option will apply a preset of some of
the control panel parameters that would otherwise
have to be programmed individually for connection to
"Cloud Mode"
the Inim Cloud service.
Refer to paragraph 4-4 "Cloud mode" preset.
Date/Time
Editable field for the system date and time.
Set local time
This button sets the local time of the PC in use.
Write on control
This button writes the local time of the PC on the
control panel.
panel
Restart
If activated, each event which activates a monostable
monostable out-
output refreshes the programmed "Monostable time".
puts
The control panel will not arm the partition if it
detects any zones that are not in stand-by status.
If, amongst the zones not in standby status, there are
Does not arm if
zones configured as "Autobypassable" or "No arm if
any of the zones
not ready" (refer to paragraph 6-1 Zones/Inputs)
are not ready
they will be indicated on the keypad. If the user still
arms the system, these zones will be inhibited
automatically and the partitions they belong to will be
armed.
Bypass tamper
If a zone is bypassed (disabled), it will also be unable
in the event of
to generate terminal tamper.
bypassed zones
No user will be allowed to delete of the following
events:
Prevents the
terminal tamper
deletion of tam-
control panel open-tamper
control panel dislodgement-tamper
per memory by
peripheral tamper
user code
peripheral loss
false key
If this option is enabled, reset of the magnetic reed
Instant reset of
sensor of wireless detectors will be signalled instantly
wireless mag-
(otherwise signalling has a maximum delay of 10
netic contact
seconds).
If this option is enabled, all the control panel
Lock installer
parameters with the exception of the installer PIN will
code
reset to the factory default settings after reset.
The control panel clock will go back automatically one
Automatic Day-
hour at 03:00 the first Sunday in October, and it will
light Saving
go forward automatically one hour at 02:00 the last
Time (DST)
Sunday in March.
Enables management of the "Contaminated smoke
detector" event.
The "Output fault" and "Detector dusty" events share
the same actions. Therefore, if either of these events
occur, the system will send the calls and activate the
Use fault output
outputs associated with the "Output fault" event.
for smoke sen-
The events log provides the proper distinction
sor contamina-
between these two events:
tion
in the event of an "Output fault", the system will
provide the description of the output in fault
status
in the event of an "Detector dusty", the system
will provide the description of the detector that
generated the event
You can start the maintenance session from the
keypad without need of opening the control panel or
moving the jumper. After exiting the Installer menu,
you can operate on the system in the same way as
Maintenance
when the control panel is placed in maintenance
mode by means of the jumper.
You must disable this option if you wish to put the
control panel in "RUN" mode.
The control panel will generate a "Sounder/flasher
Check horn
tamper" event when the passive horn disconnects
from the relay (wire cutting tamper).
26
Table 4-2: Control panel definition
Table 4-3: Control panel options
Parameter
Not available
User functions, Set
date/time
Not available
Not available
Software section
Installer menu section
Control panel
parameters
Parameters,
Programming from the Control panel
Centrali anti-intrusione
RefreshMnstblOut
OpenZonesArmLock
BypassAlsoTamper
NoUserTamp.reset
Instant restoral
LockInstall.Code
DayLightSav.time
Dust event enab.
Maintenance
Tamper siren