INIM Electronics Prime Programming Manual page 19

Anti-intrusion control panels and security systems
Table of Contents

Advertisement

Programming manual
Activation cause x
Sounder/
flasher LED
activations
Cause of deacti-
vation of
sounder and
flasher
Pressing the Start button initiates a 4 minute countdown during which the values of
the following features of the wireless sounder/flasher will be shown:
Real-time
Level / foam threshold
Level / tamper threshold
Monitoring the wireless soun-
Sounder/
flasher parame-
Communication loss signalling
ters
Enable foam tamper signalling
Enable anti-tamper signalling
Enable battery inefficient sig-
PRG/STATUS LED activation
Activation cause x
Sounder/
flasher LED acti-
vations
Cause of deacti-
vation of
sounder and
flasher
Monitoring
Pressing the Start button starts a monitoring phase on the variation of the signal
transmitted by the device and background noise detected over time.
wireless
Programming peripherals
Table 3-8: Ivy-B hardwired sounder/flasher parameters
Each sounder/flasher LED (PRG or STATUS) has a
maximum of 5 checkboxes which allow you to select
the control panel event which activates the LED.
If the "Inversion" option is not enabled, LED
activation will occur when the event is active. If the
Inversion
"Inversion" option is enabled, LED activation will
occur when the event is not active.
There are a maximum of 5 check boxes which allow
Cause x
you to select a control panel event for the
deactivation of the sounder and flasher.
If the "Inversion" option is not enabled, the sounder
and flasher will deactivate on activation of the event.
Inversion
If the "Inversion" option is enabled, the sounder and
flasher will deactivate on deactivation of the event.
Table 3-9: Air2-Hedera wireless sounder/flasher parameters
Parameter
It is possible to read on the bars the values (from 1 to
100) detected by the anti-foam and tamper sensors.
You can adjust the alarm threshold by means of the
programming fields at the side. The Default button
allows you to reset the value to the factory settings.
This section allows you to view the status of the
sounder/flasher (paragraph 21-6 Monitoring sounder/
derflasher
flashers).
It is possible to select when the sounder/flasher will
signal communication loss with the control panel:
never
only when wireless jamming affects
communication
each time communication is lost
In the latter two cases it is necessary to indicate
theWireless supervision time, in minutes, after
which if the communication continues to be absent
the sounder/flasher will activate.
The activation type can be defined in the same
section (selection of the sound, duration, flash
sequence, activation of the STATUS and PRG LEDs).
Default
Button to reset the factory default data
If selected, it enables signalling from the anti-foam,
open panel, dislodgement and battery inefficient
sensors.
nalling
Section where you can indicate the source (control
panel or sounder/flasher) of PRG and STATUS LED
activation.
The selection of one of the two LED activation sources
excludes the other.
Each sounder/flasher LED (PRG or STATUS) has a
maximum of 5 checkboxes which allow you to select
the control panel event which activates the LED.
If the "Inversion" option is not enabled, LED
activation will occur when the event is active. If the
Inversion
"Inversion" option is enabled, LED activation will
occur when the event is not active.
There are a maximum of 5 check boxes which allow
Cause x
you to select a control panel event for the
deactivation of the sounder and flasher.
If the "Inversion" option is not enabled, the sounder
and flasher will deactivate on activation of the event.
Inversion
If the "Inversion" option is enabled, the sounder and
flasher will deactivate on deactivation of the event.
Configured
sounder/flasher,
selected sounder/
flasher, Sounder
LED activations
Configured
sounder/flasher,
selected sounder/
flasher, Cause of
sounder and flasher
deactivation
Software section
Configured sounder/
flasher, selected
sounder/flasher,
Real-time
Configured sounder/
flashers, selected
sounder/flasher,
Sounder/flasher
parameters
Configured sounder/
flasher, selected
sounder/flasher,
Sounder LED
activations
Configured sounder/
flasher, selected
sounder/flasher,
Cause of sounder
and flasher
deactivation
Configured sounder/
flashers, selected
sounder/flasher,
Wireless monitoring
19

Advertisement

Table of Contents
loading