INIM Electronics Prime Programming Manual page 89

Anti-intrusion control panels and security systems
Table of Contents

Advertisement

Programming manual
Click-on the Settings button on the menu bar, set up the connection to the control panel.
in order to have the system configuration available, perform a read operation using the Read
button.
2. Change the descriptions of the partitions:
• Partition 1 - "Ground floor"
• Partition 2 - "First floor"
PROGRAMMING Partitions, "Partition 00x", Description
Click on the Partitions button on the menu on the left, the "Programming" section on the
right will show the list of available partitions.
Here, by selecting the partition to set up, it is possible to change the parameter "Description".
3. Program the zones (all connected to the control panel):
PROGRAMMING Terminals, select the terminal concerned
or
PROGRAMMING Zones, select the zone associated with the terminal concerned
To program the zone, select the Terminals button. The "Programming" section on the right
will show the graphic representation (map) of the terminals of the entire system.
By double clicking on the terminal concerned you will enter the terminal programming phase.
Device
Description
A
Roller blind detector
Motion detector
B
entrance
Magnetic contact
C
entrance door
Magnetic contact garage
D
shutter
Motion detector living
E
room
Magnetic contact win-
F
dow 1 bedroom
Magnetic contact win-
G
dow 2 bedroom
Motion detector bed-
H
room
4. Add a third partial arming scenario (Stay mode) to the default scenarios (Scenario 1
"Away mode" and Scenario 2 "Disarm") of both partitions.
PROGRAMMING Arming scenarios, "SCENARIO 003",
Click-on the Arming scenarios button on the menu on the left, the "Programming" section
on the right will show the list of available scenarios.
Here, select scenario 3, set "Stay mode" for the "Ground floor" and "First floor" partitions.
5. Associate the "Ground floor" and "First floor" partitions with the readers, and scenario 3
Stay mode (arm partially) to the default scenarios:
PROGRAMMING Readers, ChoosePeripheral, "READER 00x", Partitions
In this section you can enable the "Ground floor" and "First floor" partitions.
PROGRAMMING Readers, ChoosePeripheral, "READER 00x", Shortcut
In this section you can select the shortcut associated with the red and blue LEDs by first
selecting the "Arm/disarm" type then the scenario to associate with the LED.
Programming example
Table 22-2: Zone parameters
Partition
Zone type
Ground floor
Instant
Ground floor
Delayed
Ground floor
Delayed
Ground floor
Instant
Ground floor
Instant
First floor
Instant
First floor
Instant
First floor
Instant
Partitions, "partition", Stay
PROGRAMMING
PARTITIONS
Via keypad
Via software
PROGRAMMING
ZONES
Via keypad
Via software
Option
Balancing
None
Normally closed
Interior
Normally closed
None
Normally closed
None
Normally closed
None
Normally closed
None
Normally closed
None
Normally closed
None
Normally closed
PROGRAMMING
SCENARIOS
Via keypad
Via software
PROGRAMMING
READERS
Via keypad
Detector type
Roller blind
Generic zone
Generic zone
Generic zone
Generic zone
Generic zone
Generic zone
Generic zone
89