Click-on the Real-time option to display the following real-time features of the
sounder/flasher:
Real-time
Battery voltage
Line voltage
Temperature
Foam left/right
Read sounder/flasher
Write sounder/flasher
Sounder/
flasher parame-
ters
I-BUS loss signal delay
Sounderflasher address
Activation of LED input
Power failure
Open cover signalling
Foam tamper signalling
Blow-torch tamper signalling
Battery status
Audible signalling
Maximum audible signal time
STATUS LED ON
Flashes/minute
Enable flasher LED input
Monitor IBUS
TAMPER and FAULT outputs
If the internal temperature of the sounder/flasher indicated in the "Real-time" section
Temperature
is incorrect, you can use this section to set the real temperature value and correct the
compensation
parameter by means of the Compensation button.
18
Table 3-8: Ivy-B hardwired sounder/flasher parameters
Parameter
Voltage of the internal battery of the sounder/flasher.
Voltage detected on terminals 1 and 2 of the
sounder/flasher.
Internal temperature of the sounder/flasher read by
the thermal probe.
Values detected by the foam protection sensor (left/
right).
Tamper
Value read by the open-panel sensor
Clicking-on the Read sounder/flasher and Write
sounder/flasher buttons will allow you to set the
parameters of the sounder/flasher.
Default
Button to reset the factory default data
This is the time the sounder/flasher must wait before
signalling the loss of the I-BUS signal (expressed in
minutes).
This is the firmware version of the sounder/flasher
Version
board.
Dropdown box for the selection of the BUS address of
the sounderflasher.
The check boxes in this section allow you associate
one or more signals to each of the sounder/flasher
I-BUS loss
events.
The available signals are aligned with the wording of
each event:
FAULT output
TAMPER output
STATUS LED
Horn fault
PRG LED
Flasher
Sounder
Horn tone selection
This is the maximum time the sounder is allowed to
emit the audible signal, however, the visual signals
will continue until the device is reset.
If this option is enabled, the STATUS LED will go On
solid.
Selects the flash rate on the flasher.
Option to allow blinking on the STATUS LED and PRG
LED activated by the LED input.
If this option is enabled, the BUS will be monitored
for one minute after each control panel reset
operation and its status will be signalled on the PRG
LED as follows:
On solid - BUS not connected
1 flash per second - BUS connected but sounder/
flasher not enrolled
2 flashes per second - BUS connected and
sounderflasher enrolled
This option allows you to select the type of contact
(normally open or closed) of outputs during stand-by
status.
Centrali anti-intrusione
Software section
Configured
sounder/flasher,
selected sounder/
flasher, Real-time
Configured
sounder/flashers,
selected sounder/
flasher, Sounder/
flasher parameters
Configured
sounder/flasher,
selected sounder/
flasher,
Temperature
compensation