Name
Successful call
Successful call
Input undergoing pro-
Programming
gramming
Ongoing call
Ongoing call
SMS message not
SMSMessageFailed
delivered
Output fault
Output fault
Low credit
Low credit
Date and time change
Time modified
Resistance internal
Int. Resistance
battery
Battery short-circuit
Battery shorted
Battery disconnection
Battery disconn.
Power-supply over-
PwSupplyOverload
load
Overheating on
PwSupply Overheat
power-supply unit
Ground fault
Ground fault
Overvoltage output
Overvoltage
"x"
Overvoltage BUS
Overvolt. BUS
Low voltage output
Low voltage "x"
"x"
Low voltage output
Undervoltage BUS
BUS
Short-circuit output
Short circuit ?x?
"x"
Short-circuit output
Short circuit BUS
BUS
Overload output "x"
Overload ?x?
Overload output BUS
Overload BUS
Failed communication
with power-supply
NoCommunPwSupply
unit
Telephone call on
Tel. on number 1
Number 1 in progress
Telephone call on
Tel.on number 15
Number 15 in progress
Data synchronization
between control panel
Sync.data IP2RX
and IP2RX
IP connection lost
GPRS conn. lost
GPRS connection lost
GPRS conn. lost
Dust in smoke detec-
Detector dusty
tor chamber
General alarm
Alarm
General tamper
Tamper
Event type
Occurs when...
The call is answered
Access to system programming is autho-
rized
A call is sent
Nexus failed to send SMS message
An output fails to switch status as com-
manded
The credit remaining on the SIM card
inserted in the Nexus is below the mini-
mum credit threshold.
There is a change in the date and time.
This event will be recorded together with
the date/time before the change.
The internal resistance of the battery has
exceeded the R
i max
A short-circuit condition has been
detected on the battery connection termi-
nals
The backup battery is disconnected
Output overload is detected on the
power-supply unit
The temperature of the power-supply unit
has exceeded the allowed limit
Leakage to ground is present
A voltage of over 14.5V has been
detected on terminal "+AUX" corre-
?x?
sponding to number "x" on the mother-
board.
A voltage of over 14.5V has been
detected on I-BUS terminal "+" on the
motherboard.
A voltage below 9.8V has been detected
on terminal "+AUX" corresponding to
number "x" on the motherboard.
A voltage below 9.8V has been detected
on I-BUS terminal "+" on the mother-
board.
A short-circuit has been detected on ter-
minal "+AUX" corresponding to number
"x" on the LIVPWR100 board.
A short-circuit has been detected on I-
BUS terminal "+" on the motherboard.
A load of over 1.5A has been detected on
terminal "+AUX" corresponding to num-
ber "x" on the motherboard.
A load of over 3.5A has been detected on
I-BUS terminal "+" on the motherboard. The terminal restores to normal.
Communication between the power sup-
ply unit and the control panel has broken
down.
A call has been sent to phone number 1
A call has been sent to phone number 15 The call has ended (even in the
The IP connectivity test is enabled and
the test result in negative (failed).
Nexus has detected GPRS connectivity
trouble.
The smoke chamber of at least one of the
Air2-FD100 smoke detectors is contami-
nated by dirt or dust.
Refer to the instructions supplied with the
detector for information regarding the
respective threshold.
Any one of the zones has generated an
alarm signal.
Any one of the zones has generated a
tamper signal.
Restores when ...
End of system programming
A call ends
The remaining credit is above the
minimum credit threshold.
There is a change in the date and
time.
This event will be recorded
together with the date/time after
the change.
The internal resistance of the
battery returned to below the R
value.
value.
max
The short-circuit condition is no
longer present
The backup battery is connected
The electrical load returns below
the allowed limit
The temperature of the power-
supply unit is normal
The leakage to ground condition
is no longer detected
The normal voltage on the termi-
nal has been restored.
The normal voltage on the termi-
nal has been restored.
The normal voltage on the termi-
nal has been restored.
The normal voltage on the termi-
nal has been restored.
The short-circuit is no longer
present.
The short-circuit is no longer
present.
The terminal restores to normal.
Communication between the
power supply unit and the control
panel restores.
The call has ended (even in the
event of negative outcome)
event of negative outcome)
For future use
A connection attempt has been
successful.
The GPRS connectivity is
restored.
All smoke sensors have stopped
signalling the presence of dust.
All the zones have reset the
alarm signal.
All the zones have reset the tam-
per signal.
Pulse
Number of events
events
1
Yes
1
no
1
no
1
Yes
1
Yes
1
no
1
no
1
no
i
1
no
1
no
1
no
1
no
1
no
one for each output
"+AUX" of the
no
motherboard
1
no
one for each output
"+AUX" of the
no
motherboard
1
no
one for each output
"+AUX" of the
no
motherboard
1
no
one for each output
"+AUX" of the
no
motherboard
1
no
1
no
1
no
1
no
1
no
1
no
1
no
1
no
1
no
105