19-2
OPTIONS
ANTI-MASKING
DETECTORS
ATS4
80
The programmed "LowBattery delay" must not be programmed at more than 5 minutes.
EN50131-3 and EN50131-6 grade
3
Compliance with the EN50131-3 and EN50136-3 grade 3 standards is guaranteed by adding
to the requirements indicated in the paragraph 19-1 EN50131, Grade 2 the following.
Enable the "50131 grade 3 compatibility" control panel option(Table 4-6: Parameters for
compliance).
If the installation uses detectors with an anti-masking function, each anti-masking signal
must be managed as follows:
• Prepare an input terminal for the anti-masking signal connection.
• "Description" parameter: assign an explanatory description to the signal
• Enable "Zone fault" option
Enable the "Do not arm if zones are not ready" (Table 4-3: Control panel options)
Use an ATS4 notification appliance:
• protocol: SIA-IP with encryption
• interface: LAN (integrated on the motherboard) or PrimeLAN
Centrali anti-intrusione
Compliance with rules in force