Programming partitions
The programming of the partitions of the Prime system can be performed either via software
or from a keypad.
Click-on the Partitions button on the menu on the left, the "Programming" section will show
a list of all the available partitions and their parameters. By selecting one of these items it is
possible to set the parameters of the single partition by clicking on the
Type-in Code (Installer PIN) , PROGRAMMING Partitions
This section allows you to program the various options of the selected partition.

Partition parameters

Description
This is the editable partition label (description).
This is the Exit time window (programmable in seconds or
minutes).
If you set "0" in this field, there will be no Exit time.
Exit time
Therefore, any delayed zones belonging to the partition will
generate alarms instantly if they are not in stand-by status
when the partition is armed.
This is the Entry time window (programmable in seconds or
minutes).
If you set "0" in this field, there will be no Entry time.
Entry Time
Therefore, any delayed zones belonging to the partition will
generate alarms instantly if violated when the partition is
armed.
Entry Time 2
This is the window for the second Entry time.
This setting is the delay, expressed in minutes, which
Pre-arm time
precedes automatic-arming on a partition.
This is the time window for patrol operations
Patrol time
(programmable in minutes).
Select the timer you want to associate with the automatic-
Timers
arming operations.
Autoreset memory
If enabled, the partition alarm and tamper memory will
reset automatically when the partition arms.
on arming
If enabled, the partition will arm in "Stay" mode at the
programmed time.
Auto-arm in stay
mode
If disabled, the partition will arm in "Away" mode at the
programmed time.
Clear call queue on
If enabled, the call queue will clear when the partition
disarms.
disarm
At the bottom of the section are the buttons that directly
Events button
access the programming section of the events associated
with the selected partition.
The association of a timer to a partition will allow it to arm or disarm automatically at the ON/
OFF times set on the timer.
This function must be enabled or disabled for each individual partition.
Type-in Code (User), Activations, Auto-arm
This section lists the partitions on which to activate or not automatic arm/disarm operations
by means of the
and
Forced auto-arm operations may occur, generated by events active at the time of the auto-
arm operation.
Programming partitions
Table 5-1: Parameters for single partitions
Parameter
buttons.
Via software
button.
Via keypad
Software section
Installer menu section
Partitions,
Partitions, "parti-
selected
tion"
partition
Partitions, "parti-
tion", Options,
Events
AUTOMATIC ARM/
DISARMING
5
Chapter
5-1
AutoresetMemories
Autoarm.STAYmode
StopTelOn Disarm
31

Advertisement

Table of Contents
loading

Table of Contents