Zones/Inputs - INIM Electronics Prime Programming Manual

Anti-intrusion control panels and security systems
Table of Contents

Advertisement

6-1
Via keypad
Via software
This is the editable label which identifies the zone. At
default all the zones assume the description of the
Description
peripheral they refer to, followed by the respective
terminal.
Dropdown box for the selection of the zone type:
Type
Instant, Delayed, Viewable delayed, Route, 24hour,
Technological, Arm, Disarm, Switch, Follow, Patrol.
Dropdown box for the selection of the balancing type
(the options vary in accordance with the zone type).
Balancing
Normally open (NO), Normally closed (NC), Single
balancing, Double balancing, Double zone (without
EOL), Double zone (with EOL).
Detector type
Generic zone, Roller blind, Shock
Dropdown box for the selection of the number of
alarm cycles (between 1 and 14).
Alarm cycles
If you select "Unlimited", the zone will operate as a
"repetitive" zone.
Button for to open a window showing the zone
Wiring diagram
connection mode.
Check box to indicate the Contact-ID code associated
with the zone for the occurrence or restoral of events
such as:
Contact ID
Zone alarm
Zone tamper
Zone bypass
Zone real-time
Button for to open a window showing the zone
Wiring diagram
connection mode.
Section for the adjustment of zone detection
thresholds. The thresholds can be modified via the
number boxes or by using the bar which indicates the
levels by means of colours:
yellow - tamper/short
green - stand-by
red - alarm
Real-time
orange - double zone with one zone in alarm
status and the other in stand-by status
Clocking-on the Real-time button makes a
connection with the zone which feeds back
information regarding the thresholds. The OK button
saves the changes which will be written during the
write phase.
34

Zones/Inputs

The terminal the zone is connected to must be configured as an "input".
Type in Code (Installer), PROGRAMMING Terminals, select the terminal concerned configured as input
("I")
or
Type in Code (Installer) , PROGRAMMING Zones , select the zone concerned
To program the zone, select the Terminals button. The "Programming" section on the right
will show the graphic representation (map) of the terminals of the entire system.
Here, by double clicking on the terminal configured as a "zone" you enter programming.
or
Click-on the Zones button on the menu on the left, the "Programming" section will show a list
of all the available zones and their parameters. By selecting one of these items it is possible to
set the parameters of the single zone by clicking on the
Table 6-3: Zone parameters
Parameter
button.
Software section
Zones, selected zone
Zones, "zone"
Not available
Not available
Centrali anti-intrusione
Installer menu section
Programming terminals