Control Panel Language; Updating The Control Panel Firmware - INIM Electronics Prime Programming Manual

Anti-intrusion control panels and security systems
Table of Contents

Advertisement

This option activates a presetting on the control panel
which adheres to grade 3 of EN50131.
only the installer code can be used to delete fault
memories
the readers lock for 10 minutes after 5 consecutive
attempts to use a false key
50131 Grade 3 Com-
the keypads lock for 10 minutes after 5 consecutive
attempts to type in a false code (valid only when
patibility
the "Lock keypad" option is enabled)
bypassed zones are automatically unbypassed
when the system disarms
in the presence of ongoing faults and lost
peripherals, arming operations will require installer
code entry
The readers LEDs will remain OFF when there are no
keys near the readers themselves. As soon as a key is
held near a reader and then immediately moved away,
the reader will show the status of the LEDs for 30
seconds, after which it will switch OFF all the LEDs
Reader LED OFF
again.
During this 30 second phase, the user can hold the key
in the vicinity of the reader and select the desired
shortcut indicated by LEDs.
The status of the partitions will be hidden. If a valid
code is entered at a keypad, the real-time status will
be indicated on the keypad concerned for 30 seconds.
If partitions are armed, the real-time status of the
Hide status
system will be hidden from non-authorized users.
If the partitions are disarmed, the LEDs will function
normally, the status icons will be present and the alarm
and tamper events will be visible.
If partitions are armed, the status icons will be hidden
from non-authorized users.
If a valid code is entered at a keypad, the status of the
Hide icons
icons will be shown for 30 seconds.
The keypad will show the real-time status of the icons
when all the keypad partitions are disarmed.
If an instant-zone alarm occurs on a partition while
entry time is running, the associated actions (calls,
output activation, save to log, etc.) will not be
generated until 30 seconds after the expiry of the entry
time.
Alarm delay
If the partition (or partitions) are disarmed during this
period, the associated actions will not be generated,
however, the keypads will indicate the violation of the
instant zone.
If the control panel detects a fault, the yellow LED on
the keypads will go On and will remain On even after
the fault clears.
Fault memory LED
To switch the yellow LED Off, clear all activating causes
and reset the partition.
4-6
Via keypad
4-7
Via software
ATTENTION!
30
Table 4-6: Parameters for compliance

Control panel language

The Prime system allows you to select the language the system uses for the strings in the
User and Installer menus for the descriptions of events, faults, etc.
Type in Code (Installer), PROGRAMMING Language
Use keys
and
Obviously, after a change of language the descriptions of the various system elements such as
the zones, partitions, outputs, codes, etc., will remain unchanged.

Updating the control panel firmware

Through a direct connection between the Prime/STUDIO software and the Prime control panel,
it is possible to update the control panel firmware to the latest revision available at the time of
the software release.
Click-on the Firmware upgrade button on the menu on the left, the "Programming" section
will show the buttons for the updating procedure.
Click-on the Prime panel button. A section will open with the available updates and the Start
procedure button.
In order to avoid invalidating the procedure, do not switch off or disconnect the PC or Prime
control panel during the updating process.
to select the desired language and OK to confirm.
Centrali anti-intrusione
Regulatory
Parameters
compatibility,
Parameters
50131, Grade 3
50131
50131ReaderLedOFF
50131StatHidden
50131IconsHidden
50131AlarDelayed
50131WarnLedMem
Programming from the Control panel

Advertisement

Table of Contents
loading