Programming manual
If you select this option, the control panel will reset
Reset CONTACT-ID
all the event codes used for the CONTACT-ID
protocol to factory default (refer to paragraph 12-1-
event codes
1 Voice and digital dialer for the event).
If you select this option, the control panel (after
requesting confirmation) will implement incremental
Reassign the CCC in
numbering (from "1") in the "CCC" field of the
sequential mode
CONTACT-ID protocol for the events relative to the
zone.
If you select this option, the control panel (after
Reset SIA protocols to
requesting confirmation) will reset to factory default
default
all the SIA parameters of all events.
Pressing the OK button will delete all the control
panel events, both on activation and restoral:
Delete events pro-
gramming
Pressing the OK button will delete all the data
relating to the Air2-BS200 device.
The data relating to the detectors and wireless
Wireless data reset
keyfobs will not be deleted, nor will the devices
simulated by the Air2-BS100 transceiver be deleted
from the configuration.
Pressing the OK button will delete all the
Reset PIN codes
programmed User PIN codes and will reset the
default codes.
Pressing the OK button will delete all the enrolled
Reset keys
keys.
This option allows the control panel to learn the balancing of all the zones automatically
(Patent Pending).
The zone-balancing options are:
• Normally Open
• Normally Closed
• Balancing (Single balancing)
• Double balancing
• Roller blind with EOL
The balancing settings which are not acquired accurately are:
Roller blind without EOL (which is classified as a normally-closed generic zone)
• Double zone without EOL (which is classified as a normally-closed generic zone)
• Double zone with EOL (which is classified as a generic zone with Double balancing)
In order to allow accurate acquisition of the balancing settings of all the zones, you must:
1. Wire and select the balancing settings of all the zones.
2. Ensure, as far as possible, that all the zones are in stand-by status
3. Activate the "Learn zone bal." option.
4. Verify that the operation has been carried properly and that all the settings are accurate
(if any zones are not in stand-by status during this process their balancing will not be
acquired accurately).
5. Set manually any inaccurate settings.
Default settings
Table 17-1: Reset operations
All outputs
All calls
All options
Events
maintenance,
Reset to default
CONTACT-ID
protocols
,
Events
maintenance,
Reset SIA
default
Not available
Not available
Not available
Not available
CONTACTIDDefault
CONT-ID enumer.
SIA defaults
DeletePrg.events
WLS data reset
Reset PIN default
Reset keys only
AUTO-LEARN
BALANCING
75