Programming manual
This option activates the sounder for a brief period
during partition stay/away arming and disarming
Squawk
operations. This audible signal indicates that these
operations have been executed successfully.
If enabled, all the system keypads will emit an
Sound alarm on
audible signal in the event of an alarm or tamper
keypad
event on any one of the partitions they belong to.
Enable control
This option, enabled by default, provides protection
panel anti-dis-
against tamper on the control panel (tear-off and tilt
detection).
lodgement
This parameter allows the selection of the supervision
time of wireless devices. On expiration of the
Wireless super-
programmed time, any wireless devices which do not
vision time
respond will be signalled as lost.
Accepted values: 12 to 250 minutes.
This parameter allows you to program the delay,
expressed in minutes, between an "AC Mains failure"
Mains fault delay
event and "AC Mains failure" event signalling.
Accepted values: 0 to 250 minutes.
This parameter allows you to program the delay,
expressed in minutes, which will be applied before
Low battery
"LowBattery" events are actually signalled after
delay
detection.
Accepted values: 0 to 250 minutes.
This is the BUS communication speed (38.4 / 125 /
BUS speed
250 kbps).
This parameter allows you to select the volume level
Outgoing Tele-
of outgoing voice messages during playback over the
phone voice vol-
phone.
ume
Accepted values: 10 to 100 minutes.
This parameter allows you to select the volume level
of the incoming telephone signal. This is a useful
Incoming Tele-
parameter for the understanding of DTMF tones.
phone volume
Accepted values: 1 to 80 minutes.
Parameter for selecting the communication channel
with the Cloud:
Use LAN
Cloud options
Use Nexus
If both are selected priority will be given to the LAN.

Programming IP parameters

The connectivity to the Prime control panel LAN is subject to the configuration of the network
itself.
The manufacturer strongly recommends that you contact the network administrator for the
correct configuration.
IP Address
Subnet mask
Gateway
DNS
Connection parameters
Communication
port
Web server port
SSL port
Obtain an IP
If this option is enabled the above items are not
address auto-
required. The protocol used is DHCP.
matically
This option enables UPnP protocol which automatically
Enable UPnP
activates "port-forwarding" through the network router
of the communication, web and SSL ports.
Programming from the Control panel
Table 4-3: Control panel options
Table 4-4: IP connection
Parameter
Not available
Not available
Other parameters,
Software section
Installer menu section
IP connection
Other parameters,
parameters,
Connection
parameters
Not available
Parameters,
Not available
Squawk on arming
Alarm on keypads
Other parameters,
Wireless superv.
Mains fail.Delay
LowBattery delay
OverThePhoneVol.
Tel. input gain
Cloud options
4-3
IP parameters
Enable DHCP