The operations necessary for the reset of the factory default data vary and can be carried out
by the installer through one of the means of access the installer has to the control panel:
• the FACTORY and RESET buttons on the control panel PCB
• the keypad, via the installer menu
• the Prime/STUDIO software
Reset of the factory default programming data deletes all the previously programmed
parameter settings.
Reset of the factory default programming data does not cancel the connection of the control panel to the
Cloud.
1. Press and hold the FACTORY button on the motherboard.
2. Press and release the RESET button on the motherboard.
3. Release the FACTORY button.
Within 70 seconds the control panel will reset the parameters factory default values, enroll all
the peripherals currently on the I-BUS and, if at least one keypad is connected, will ask you to
select the Language.
Reset to factory default will not clear the events log.
Type in Code (Installer), PROGRAMMING Factory settings
This section allows you to reset to default settings all the control panel parameters, auto-learn
zone balancing values, auto-enroll I-BUS peripherals and restore the event codes of
CONTACT-ID reporting format.
Following each of these operations, the control panel will ask for confirmation by pressing the
OK button.
The Prime/STUDIO software program allows you to reset the control panel default values only
for the following parameters:
• digital dialer parameters
• "CCC" field of CONTACT-ID protocol of the zones
• phone calls on activation and restoral
• outputs on activation or restoral
• message playback on keypads on activation or restoral
• SIA protocol parameters
Table 17-1: Reset operations
Parameter
If you select this option, the control panel will reset
all programming data to factory default settings.
If you select this option, the control panel will
gather and and save the balancing settings of all the
zones automatically (Patent Pending).
If you select this option, the control panel will
reconfigure the IBUS and enroll in the new
configuration all the peripherals that respond to the
auto-enroll peripheral command.
Default settings
Software section
Not available
Not available
Not available
Centrali anti-intrusione
Installer menu section
Default settings,
Factory data
Learn zone bal.
Autoenroll periph.
Default settings