Walk Test; Monitoring The Power Supply - INIM Electronics Prime Programming Manual

Anti-intrusion control panels and security systems
Table of Contents

Advertisement

LED
Green
Tamper
Red
Green
Antifoam
Red
Green
Battery fault
Red
Green
Sounder
active
Red
21-7
Via keypad
Via software
21-8
Via software
86
In this section, the monitoring window lists the parts of the sounder/flasher whose status is
represented by icons/LED:
Table 21-4: Wireless sounder/flasher status LED
Status
Sounder/flasher not in tamper
status
Sounder/flasher in tamper
status (open or dislodged)
Foam level below alarm
signalling threshold
Foam level above alarm
signalling threshold
Battery charged
Battery charge low (below
40%)
Audible signalling Off
Audible signalling On
Instead, the "Wireless monitoring" sub-section provides the Start button that starts a
monitoring on the variation of the signal transmitted by the device and background noise
detected over time.

Walk test

This section provides a quick and easy way of testing all the configured inputs.
After initializing the Walk test, all the operator need to do is walk through the protected
partitions and then check the detection capacity of the inputs via the system keypad or Prime/
STUDIO software application.
Type-in Code (Installer) , PROGRAMMING Walk test .
Access to this section opens the full list of configured zones on the keypad display.
As these input zones are violated by the operator carrying out the walk test, they will be
cleared from the list and the keypad will emit a long beep.
You can consider the outcome of test positive when there are no zones left on the list.
Click-on the Monitoring button on the menu bar, then go to the "Programming, Sounder/
flashers" section.
The list of zones and the Start Walk test button will be shown.
Once the test starts, the operator can walk through the entire area protected by the system
and verify the correctness of the detection capacity of the inputs by means of the information
reported in this section, marking the violated areas with a red dot and the time of the
violation.
The Print Walk test button allows the so0ftware to print the test results.

Monitoring the power supply

The software has a section for monitoring the power supplies, through LEDs with the relative
colours and values shown in the readings.
Click-on the Monitoring button on the menu bar, then go to the "Programming, Power"
section.
After clicking-on the Start monitoring button this section will show:
• data relating to the power supplied to the control panel
•• primary power supply
•• power and secondary power supply
LED
Green
Flasher active
Red
Green
STATUS LED
ON
Red
Green
PRG LED ON
Red
Signal recep-
tion level
Battery level
Centrali anti-intrusione
Status
Visual signalling Off
Visual signalling On
STATUS LED Off
STATUS LED On
PRG LED Off
PRG LED On
This series of notches
represents the reception level
of the wireless signal of the
device as received by the Air2-
BS200 transceiver.
Percentage of the sounder/
flasher battery charge.
Monitoring the control panel