Programming manual

Outputs

Prime control panels always have 5 outputs available which are constituted by:
• relay output (terminals 1-2-3)
• open-collector output OC1 (terminal 5)
• open-collector output OC2 (terminal 6)
• supervised output AUX1 (terminal 11)
• supervised output AUX2 (terminal 23)
Furthermore, all terminals from T1 to T10 can be used as OC collectors.
The outputs configured on Flex5/P and Flex5/U expansion boards are open-collectors (OC).
The output on terminal T5 can be configured as a dimmer type output, to be used as an
analog output (industrial standard 0-10V).
The 5 outputs on the Flex5/DAC expansion board can be configured as:
• Relay output
• Triac ON/OFF output (default setting)
• Triac dimmer output
The terminal pairs of the Flex5/DAC OUT1-OUT2 and OUT3-OUT4 are provided with the
interlock function which is required in applications with, for example, roller blind motors.
Activated by the respective option, which must be activated for both terminals in the pair. This
function has the purpose of inhibiting the simultaneous active status of the associated
terminals.
The outputs configured on the keypads are all open-collector type outputs.
Outputs
Control panel terminals
Expansion terminals
Flex5/DAC terminals
Keypad terminals
icon on software
Type in Code (Installer), PROGRAMMING Terminals, select the terminal concerned configured as con-
trolled output ("H")
or
Type in Code (Installer) , PROGRAMMING Outputs , select the output concerned
To program the output, select the Terminals button. The "Programming" section on the right
will show the graphic representation (map) of the terminals of the entire system.
Here, by double clicking on the terminal configured as "output", you enter the programming
mode.
or
Click-on the Outputs button on the menu on the left, the "Programming" section will show a
list of all the available outputs and their parameters. By selecting one of these items it is
possible to set the parameters of the single output by clicking on the
If the stand-by status of the output is determined by the occurrence of an event, the output will still not
return to stand-by status during programming mode.
This is the editable output label (device description).
At default all the outputs, except for the 3 outputs on
Description
the control panel motherboard, assume the
description of the peripheral they refer to followed by
the respective terminal.
Check box where you can indicate the monostable
Monostable time
time in the case in which the"Monostable" option is
activated.
Check box for the selection of one of the 80 icons
available (refer to Appendix C, Available Icons) that
Icon
can be associated with the "Output activation"
shortcut associated to the selected output.
Programming terminals
Table 6-6: Outputs - terminal type
Generic (OC)
any
any
any
any
Table 6-7: Output parameters
Parameter
Relay
Dimmer
NO NC COM
None
any
None
button.
Software section
Outputs, selected
outputs
6-2
None
T5
any
None
Via keypad
Via software
Note
Installer menu section
Outputs, "output"
Not available
37