Compliance 50131 Grade 3 - INIM Electronics Prime Programming Manual

Anti-intrusion control panels and security systems
Table of Contents

Advertisement

Programming manual
Event
I-BUS fuse fault
Battery fault
Mains failure
Expansion tamper
Keypad Tamper

Compliance 50131 grade 3

The Prime/STUDIO software provides a section for a configuration of the control panel that
complies with grade 3 of 50131 regulations.
However, total respect of the said regulations is obtained by appropriately setting also the
other options related to grade 2. For this purpose refer to Chapter 19 Compliance with rules
in force..
This section allows you to select which faults or events, other than zones in
alarm status, will be signalled as system security-risk conditions when the
partition arms.
The zone protection fuse on the control panel is not
Zone fuse fault
operational (blown)
I-BUS fuse fault
The I-BUS protection fuse is not operational (blown)
Low battery
The backup battery is low
Mains failure
The primary power supply 230V~ fails
Telephone line down
The land line is not working
Jamming
Wireless interference detected
The battery of a least one wireless detector must be
Low battery wireless
replaced
Loss of at least one wireless detector has been
Wireless zone loss
signalled (supervisory time expired)
This warning groups together the following events:
Loss or tamper ongo-
ing
GSM BUS fault
Nexus device fault
Violation has occurred on one or more zones with the
Faults on zones
"Fault zone" option enabled.
Faults on sounder/
Fault present on one of the sounder/flashers
flashers
Contaminated smoke
The smoke chamber of at least one of the Air2-FD100
smoke detectors is contaminated by dirt or dust.
sensor
General power-supply
Fault present on the power supply or one of the power
sources
faults
Keypad faults
Fault present on one of the keypads
The IP connectivity test is enabled and the test has
IP connection lost
failed
Programming from the Control panel
Table 4-5: Preset events for the Cloud
Communication to Cloud in case of
Activation
Restoral
Yes
Yes
Yes
Yes
Yes
Table 4-6: Parameters for compliance
Parameter
Control panel open
Dislodged panel
Expansion tamper
Keypad Tamper
Reader Tamper
Sounder flasher tamper
Nexus tamper
Expansion loss
Keypad Loss
Reader Loss
Sound.flash.Loss
Nexus loss
Event
Yes
False key
Yes
GSM fault
Yes
Input undergoing programming
Yes
Output fault
Yes
Low credit
Not available
Not available
Not available
Not available
Communication to Cloud in case of
Activation
Yes
Yes
Yes
Yes
Yes
Software section
Installer menu section
Regulatory
compatibility
Other parameters,
Forced arming
FaultForNotReady
faults
Faults on sounder/
Restoral
No
No
Yes
No
No
4-5
Zone fuse fault
IBUS fuse fault
Low battery
Mains failure
Tel. line down
Jamming
Low battery WLS
WLS zone loss
LossTamp.ongoing
Nexus fault
Faults on zones
flashers
Detector dusty
Power faults
Keypad faults
IP conn. lost
29