Proximity Readers - INIM Electronics Prime Programming Manual

Anti-intrusion control panels and security systems
Table of Contents

Advertisement

3-2
3-2-1
Via software
Via keypad
WIRELESS
READERS
Via software
14
In order to change the Alien parameter settings, your computer must be connected to the
USB port of the keypad.
Table 3-3: Touch-screen keypad parameters
Communication
This option allows you to select the connection port to the
Alien user interface from those found by the PC.
port
Refresh
Key for the connection upgrades detected by the PC.
Check box for the selection of the Alien user interface
Model
model.
Available Skin
Selection of skins available for the Alien user interface.
Button to display in the lower image only the background
Background
of the Alien keypad.
Button to display the background of the Alien keypad
All
complete with buttons.
Default
Button to display the default skin for the selected theme.
Clean
Button to clear the selected graphics.
Write skin
Button to install the selected skin on the keypad.
Write icons
Button to install the selected icon buttons on the keypad.
The image at the bottom of the "Alien Graphics" section allows the display of the selected
graphics for the Alien keypad
You can load an image from the PC by double-clicking on the background or button icons.
The image requirements depend on the device model:
• Alien/S skin:
-
- the background file must be a .jpg file with a maximum size of 120 kbytes,
480x272 pixels
-
- each of the 8 main buttons must be a .jpg file with a maximum size of 12 kbytes,
109x88 pixels
• Alien/G skin:
-
- the background file must be a .jpg file with a maximum size of 120 kbytes,
800x480 pixels
-
- each of the 8 main buttons must be a .jpg file with a maximum size of 12 kbytes,
109x88 pixels

Proximity readers

Setting up readers in the system layout
Once the solution of the installation to be designed has been opened, access the "System
layout" section on the right. Here you can select the reader to be configured and add it to the
configuration by double-clicking on the mouse.
In the section on the left, you can increase the number of readers in the layout by clicking-on
the Readers button.
To remove a reader from the structure, access the programming section by clicking on the
relative key in the menu on the left then, from the list displayed, click on the Delete button
that corresponds to the line of the reader to be deleted.
Type-in Code (Installer PIN) , PROGRAMMING Readers , Enablements
This section allows you to add/remove readers from the configuration, by means of keys
and
.
During the enrolling phase the Air2-BS200 wireless transceiver is integrated into the Prime
system by simulating:
• a reader, with the address programmed via the module itself (ADD), by means of buttons
P1 and P2 on the PCB (for details refer to the Module manual)
• up to 10 expansions, at addresses ADD, ADD+1, ... ADD+9, to manage terminals and to
be configured using the "System Layout" page in the Prime/STUDIO software.
Once the reading procedure has been carried out from the control panel, clicking on the
Proximity readers button in the menu on the left in the "Programming" section opens the
list of configured readers. The reader simulated by the Air2-BS200 transceiver is the one with
the "ADD" address set by the module itself.