4. For Air2 devices press the ENROLL button.
5. If the device to be enrolled is an output connected to a terminal of any device with an
Air2-MC300 output terminal, you must enable the "Broadcast RF" zone option (refer to
Table 6-9: Wireless parameters).
Once done, you must step back to the configuration of the terminal and configure it as
an "OUTPUT".
The "Broadcast RF" option must be enabled for each terminal of the Air2-MC300 device concerned.
6. Enroll all remote controls in the same way as you would enroll keys, and select as the
reader the one with the same address as the expansion.
7. Set the parameters of the zones, outputs and keypads.
Programming wireless terminals
This section allows you to enroll a wireless detector
Enroll
which has not yet been enrolled on the terminal
concerned.
Type of device to be enrolled (Table 6-8: Wireless
Type
terminal types).
Section to delete from the terminal in question.a
Remove
previously enrolled wireless detector.
The "Wireless" section contains the parameters for
adjustment of the detector sensitivity of the
previously enrolled devices and their functions.
Sensitivity
These parameters vary depending on the type of
wireless terminal to be configured (refer to Table 6-8:
Wireless terminal types and Table 6-10: Wireless
detector sensitivity).
Tamper on
Detects tamper on the Air2-MC300 magnetic-contact
unused reed
when both reeds are in stand-by status.
relays
In order to increase battery life, the PIR detector will
deactivate when the partitions it belongs to are
disarmed and will only activate when the partitions it
Disable detector
belongs to arm.
when partition is
Deactivated detectors do not generate alarms. When
disarmed
the partitions arm, there may be a delay of up to 3
minutes before the detector receives the activation
command.
The red LED on the device provides visual signalling
of alarm or tamper conditions on the device itself.
Use detector LED
This option will be enabled on all the terminals of the
Air2 device.
This option assures the activation/deactivation of the
output within 2 seconds of the control panel
Broadcast RF
command. Valid only for terminals T1 and T2 of Air2-
MC300 configured as outputs.
If this option is disabled, open/dislodgement tamper
Bypass tamper
on Air2 devices will not generate the respective
events.
Programming terminals
Table 6-8: Wireless terminal types
Double
Double
Double
Double
Table 6-9: Wireless parameters
Parameter
MC200 magnetic contact
Curtain detector
Directional detector
Dual technology detector
Software section
Selected terminal,
Wireless
Selected terminal,
Wireless, Options
Cont.Magn.MC200
Curtain detector
Curtain direction
Dual T detector
Note
6-5-2
Installer menu section
Terminals, "terminal",
Wireless
Enroll device
Delete device
Terminal type
Terminals, "terminal",
Options,
TampReed/FollPir
Use sensor LED
Broadcast RF
DisableTamperWLS WLS