A zone that monitors the inside of the protected
building.
Interior
If a partition that a zone belongs to is armed in Stay
mode, it will be unable to generate alarms.
A zone with this attribute will be bypassed
automatically by the control panel if, at the moment
of arming the partitions the zone belongs to, it is not
in stand-by status.
Autobypassable
The zone will be unbypassed automatically when it
restores to standby or when the partition it belongs to
is disarms.
A zone with this attribute cannot be bypassed,
Unbypassable
manually (by the user) or automatically (by the
control panel).
A zone with this attribute will generate "Chime on
partition" events, if violated when the partitions it
belongs to are disarmed.
Keypads which have partitions in common with the
Chime
chime zone will emit an audible signal when the
"Chime on partition" event occurs. If all the partitions
the zone belongs to are armed, the zone will operate
as programmed.
A zone with this attribute cannot generate alarms
(activate audible and visual signalling devices).
Test
However, any alarm events that occur will be saved to
the events memory.
If this option is enabled, the zone will operate as an
No- Unbypass-
"Autobypassable" zone, with the difference that it will
able
be automatically unbypassed when the partition next
disarms.
If this option is enabled, the zone, even if it is a 24H,
automation or delayed zone, will not arm when it is
not in stand-by status. If this option is selected for a
No arm if not
24H or technological zone, it can be used together
ready
with the control panel option: "Does not arm if any of
the zones are not ready", for the management of the
"anti-masking" function on duly capable detectors.
If this option is enabled, delayed zone will activate
Activate Entry
the second partition entry time. If this option is not
enabled, delayed zones will activate the first partition
Time 2
entry time.
If this option is enabled and the zone passes from
stand-by status to alarm status while the partition
exit time is running, the exit time will be forced to 15
Last exit zone
seconds. If the zone passes from alarm status to
standby status, the exit time will be forced to 5
seconds.
If this option is enabled, a zone which has been
Unbyp. on dis-
bypassed by a user, will be automatically unbypassed
arm
when the partition next disarms.
Activation of a zone with this configuration generates
an instant alarm even when the partition it belongs to
is disarmed. However, audible and/or visual signalling
Hold-up
devices will not be activated (silent alarm). Therefore,
calls generated by the alarm will not be revealed
audibly or visually on the keypad display and LEDs.
If this option is enabled, violation of the zone will
Fault zone
generate a zone alarm event and contribute to fault
signalling (yellow LED on the keypad).
36
Zone
Control panel terminals
Expansion terminals
Keypad terminals
icon on software
Table 6-5: Zone options
Parameter
Table 6-4: Zones - detector type
Generic
Roller blind
any
any
T1, T2, T3, T4
any
none for Alien/G
Software section
Zones, selected zone,
options
Centrali anti-intrusione
Shock
any
any
T1, T2, T3, T4
any
any
none for Alien/G
Installer menu section
Zones, "zone", Options
Delay time 2
Programming terminals