G
Appendix
Symbol/Initials
TM
TB
SM
SB
Symbol/Initials
These outputs will deactivate if a Stop alarm, Reset partition or Disarm operation is carried out while the monostable time
A
of the main output is running.
B
These outputs will deactivate only when the event clears after expiry of the monostable time of the main output.
These outputs, due to the continuous flasher function, will not deactivate automatically.
After the expiry of the monostable time on the main output, to switch off the SB flashers on the alarm signalling devices,
C
it is necessary to:
trigger an event which applies a Stop pattern to the SB flashers
reset the partition
D
These outputs will deactivate only when the event clears.
These outputs will deactivate if, when an event is active, a Stop alarm operation, reset or disarm partition command oper-
E
ation is carried out.
These outputs, due to the continuous flasher function, will not deactivate automatically. In order to deactivate the SB
flashers of the device on termination of the event, you must:
F
trigger an event which applies a Stop pattern to the SB flashers
reset the partition
G
These outputs will deactivate when the respective monostable time expires
Event groups
Zone Alarm
terminal tamper
partition alarm
partition tamper
Control panel open
Dislodged panel
Expansion tamper/loss
Keypad tamper/loss
Reader tamper/loss
Sounder/flasher tamper/loss
Jamming
Wireless zone loss
Telephone line down
other events
106
Combination of outputs triggered by events
This appendix explains the behaviour of the outputs programmed in the "Outputs" and "Other
outputs" parameters of each event together with the activation and deactivation modes
("Tone types" parameter) of the sounder/flashers on the BUS.
Tabella G-1: Output typology
Tabella G-2: Functioning and deactivation of the outputs
Tabella G-3: Output combinations
Description
Output on terminal/Relay/OC1/OC2 - monostable
Output on terminal/Relay/OC1/OC2 - bistable
Sounder/flasher output with limited flasher time
Sounder/flasher output with unlimited flasher time
Description
Principal output
TM
TB
SM
A G
D E
A G
A G
D E
A G
G
D
G
Centrali anti-intrusione
Other outputs
SB
TM
TB
A G
A B
A G
E G
D G
E G
A G
A B
A G
F
E G
D G
E G
A G
A D
A G
E G
D G
E G
A G
A B
A G
F
E G
D G
E G
G
B
G
D
G
B
F
G
C
Combination of outputs triggered by events
SM
SB
A C
F
A C
F
A C
C
A C
C
G
C
G
F
G
C
G
C