Maintenance Of Events; Output Scenarios - INIM Electronics Prime Programming Manual

Anti-intrusion control panels and security systems
Table of Contents

Advertisement

Shortcuts
Activate scenario
Activate output
Deactivate output
Zone bypass
Unbypass zone
Disable code
Enable code
Disable key
Enable key
Activate thermostat
Deactivate thermostat
Dimmer up
Dimmer down
Delete alarm memory
12-2
Reset CONTACT-ID
Button to reset the default values of the digital
communicator for all the events.
default
The sections with a Delete button allow you to
Delete activation/
delete all the outputs associated with the activation/
restoral outputs
restore actions of each event.
The sections with a Delete button allow you to
Delete activation/
delete all the telephone calls associated with the
restoral calls
activation/restore actions of each event.
The sections with a Delete button allow you to
Delete voice message
delete all the voice message on keypad playbacks
playbacks on activa-
associated with the activation/restore actions of
tion/reset
each event.
This section provides a Reset default button that
Reset SIA protocols to
resets the default settings of SIA protocol codes for
default
all the events.
This section provides a Delete Shortcuts button
Delete shortcuts on
that cancels the "Shortcut on event" parameters on
event
all the events.
12-3
Via software
60
Table 12-5: Shortcut on event
Shortcut that activates the scenario selected in the check box alongside.
Shortcut that activates the scenario selected in the check box alongside.
Shortcut that deactivates/activates the zone selected in the check box along-
Shortcut that deactivates/activates the code selected in the check box along-
Shortcut that deactivates/activates the key selected in the check box along-
Shortcut that activates the keypad thermostat in the operating mode selected
in the check box alongside.
Shortcut that deactivates the keypad thermostat selected in the check box
Shortcut that increases/decreases by 5% the value of the voltage supplied to
the dimmer output selected in the check box alongside.
Shortcut that deactivates the outputs relative to zone/partition alarm and
tamper events and deletes the partition and system alarm and tamper mem-
This shortcut operates on the partitions selected for the scenario.

Maintenance of events

Table 12-6: Single event parameters
Parameter

Output scenarios

It is possible, exclusively via the Prime/STUDIO software, to associate the activation of an
output scenario with the activation and restoral of each event.
The Prime control panel provides 50 output scenarios, each with a maximum of 10 outputs.
Programming occurs in two phases: the first is the definition of the scenarios, the second is
the assignment to the activation and restoral of the event.
Click-on the Events button on the menu on the left, the "Programming" section on the right
will show the "Output scenarios".
Function
side.
side.
side.
alongside.
ories.
Software section
Event
maintenance
Centrali anti-intrusione
Parameter
One of the 30 shortcuts available
One of the configured outputs
One of the configured zones
One of the available codes
One of the available keys
One of the keypads available
Thermostat operating mode
One of the keypads available
One of the outputs configured as
dimmer
One of the 30 shortcuts available
Installer menu section
Default settings
CONTACTIDDefault
Not available
Not available
Not available
Default settings
SIA defaults
Not available
Programming events