RT9150E OPERATOR MANUAL
Lube Point
Item
Description

Hoist

120
Drum
CAUTION: Do not mix synthetic oil with mineral based oil.
Boom Pivot
121
Bearing
Grove
Approved
Figure No.
Lubricant
SGL Synthetic
Gear Lube -
Figure 5-10
API GL4 + SAE
75W-90
02313611
EP-MPG
Extreme
Pressure
Figure 5-10
Multipurpose
Grease
6829003477
6829104275
Published 2-23-2017, Control # 644-00
Lube
Lube Interval
Capacity
• Check and fill every
50 hours or weekly
4 quarts
• Drain and fill every
(4 liters)
1000 hours or 12
months
Until
grease
500 hours or 6 months
extrudes
LUBRICATION
Application
Ensure hoist is level.
The oil must have
settled for 20
minutes with the
temperature in the
21°C ± 7°C (70°F ±
20°F) range. The oil
level must be
between the 'MIN'
and 'MAX' marks on
the sight gauge.
Variations in oil
temperature will
cause oil level to
fluctuate.
To add or refill the
oil, remove hose at
top of sight gauge.
Fill hoist through
hose until the oil
level is visible
between the 'MIN'
and 'MAX' marks on
the sight gauge.
4 grease fittings, 2
on each side
5