Item
Description
Enter outrigger
2
span, F2
Enter swing range,
3
F3
4
Enter reeving, F4
Maximum load
5
display
Grove
OPERATING CONTROLS AND PROCEDURES
Graphic
Published 2-23-2017, Control # 644-00
Explanation
• Start Input mode: press the F2
button (1) once, symbol turns green
• Input mode on: press either the F5
button
or the F6 button
to bring up the next outrigger
configuration(2):
100%, full extend
50%, mid-extend.
Refer to Outrigger Deployment, page
3-82.
• Start Input mode: press the F3
button (1) once, symbol turns green
• Input mode on: press either the F5
button
or the F6 button
to bring up the next permissible
swing range (4):
(1) 360° swing range
(2) Working position 0° to the rear *
(3) Working position 180° to the
front *
* Swing gear must be off.
Refer to Swing Range, page 3-83.
• Start Input mode:
For main hoist: press the F4
button (4) until symbol (1) is green
For auxiliary hoist: press the F4
button (4) until symbol (2) is green
• Input mode on: press either the F5
button
or the F6 button
To change reeving by one line (3)
and display the relevant maximum
load (5) for that reeving.
Refer to Entering the Reeving, page 3-
83.
Maximum load in tons (t) or kilo pounds
(klbs) for displayed RCL code.
Refer to the RCL Monitoring Submenu,
page 3-86 for more information.
once,
once,
3
once:
3-79