Folding Deflection Sheaves - Manitowoc Grove RT9150E Operator's Manual

Hide thumbs Also See for Grove RT9150E:
Table of Contents

Advertisement

SET-UP AND INSTALLATION
Disconnecting the Hydraulic Connection
2
3
1.
Remove the hose lines (2) from the connections (1)
(Figure 4-53).
2.
Close off the hose lines and the connections (1) with the
protective caps.
3.
Secure hoses in holder (1) on the 11 m (36 ft) extension.

Folding Deflection Sheaves

Deploying the Rear Deflection Sheave
Pinch Hazard!
Always hold the deflection sheave by the handle when
removing the pin. You might get your fingers crushed if
you hold the sheave by the side plates.
4-36
1
7567-38
FIGURE 4-53
CAUTION
Published 2-23-2017, Control # 644-00
RT9150E OPERATOR MANUAL
1.
Remove the retaining clip from the pin (2) (Figure 4-54).
2
3
2.
Hold the deflection sheave by the handle (1) and pull out
the pin (2).
3.
Fold the deflection sheave (3) up and fasten it in this
position with the pin (2).
4.
Secure the pin (2) using the retaining clip.
Stowing Rear Deflection Sheave
1.
Remove the retaining clip from the pin (2) (Figure 4-54).
2.
Hold the deflection sheave by the handle(1) and pull out
the pin (2).
3.
Fold the deflection sheave (3) down and fasten it in
position with the pin (2).
4.
Secure the pin (2) using the retaining clip.
3
1
2
1
7567-20
FIGURE 4-54