5.2.4 Detailed parameters 2

Item
Acceleration time 1
Pr.25
Acceleration time 2
Pr.26
Acceleration time 3
Pr.27
Deceleration time 1
Pr.28
Deceleration time 2
Pr.29
Deceleration time 3
Pr.30
Pr.31
JOG speed limit value
Pr.32
JOG operation acceleration
time selection
Pr.33
JOG operation deceleration
time selection
Pr.34
Acceleration/deceleration
process selection
Pr.35
S-curve ratio
Pr.36
Sudden stop deceleration
time
Pr.37
Stop group 1 sudden stop
selection
Pr.38
Stop group 2 sudden stop
selection
Pr.39
Stop group 3 sudden stop
selection
Pr.40
Positioning complete signal
output time
Setting value, setting range
Value set with GX Works2
1 to 8388608 (ms)
The setting range differs depending on the "
0:
Acceleration time 0
Pr.9
1:
Acceleration time 1
Pr.25
2:
Acceleration time 2
Pr.26
3:
Acceleration time 3
Pr.27
0:
Deceleration time 0
Pr.10
1:
Deceleration time 1
Pr.28
2:
Deceleration time 2
Pr.29
3:
Deceleration time 3
Pr.30
0 : Trapezoid acceleration/
deceleration process
1 : S-curve acceleration/
deceleration process
1 to 100 (%)
1 to 8388608 (ms)
0 : Normal deceleration stop
1 : Sudden stop
0 to 65535 (ms)
Chapter 5 Data Used for Positioning Control
Value set with sequence
program
1 to 8388608 (ms)
Unit setting
Pr.1
0
1
2
3
0
1
2
3
0
1
1 to 100 (%)
1 to 8388608 (ms)
0
1
0 to 65535 (ms)
0 to 32767
: Set as a
decimal
32768 to 65535 : Convert into
hexadecimal
and set
5 - 40
Buffer memory address
Default
LD77MS2
value
LD77MS4
36+150n
37+150n
38+150n
39+150n
40+150n
41+150n
1000
42+150n
43+150n
44+150n
45+150n
46+150n
47+150n
48+150n
".
20000
49+150n
0
50+150n
0
51+150n
0
52+150n
100
53+150n
54+150n
1000
55+150n
56+150n
0
57+150n
58+150n
300
59+150n
LD77MS16