Mitsubishi Electric MELSEC-LD77MS2 User Manual page 303

Hide thumbs Also See for MELSEC-LD77MS2:
Table of Contents

Advertisement

Set with a hexadecimal.
Setting
H
value
b15
b12
b8
Buffer
memory
LD77MS2/LD77MS4
Buffer
Setting items
memory
b0
Axis 1 Upper limit signal (FLS)
Axis 1 Lower limit signal (RLS)
b1
b2
Axis 1 Near-point dog signal (DOG)
b3
Axis 1 STOP signal (STOP)
b4
Axis 2 Upper limit signal (FLS)
b5
Axis 2 Lower limit signal (RLS)
b6
Axis 2 Near-point dog signal (DOG)
b7
Axis 2 STOP signal (STOP)
1928
b8
Axis 3 Upper limit signal (FLS)
b9
Axis 3 Lower limit signal (RLS)
b10
Axis 3 Near-point dog signal (DOG)
b11
Axis 3 STOP signal (STOP)
b12
Axis 4 Upper limit signal (FLS)
b13
Axis 4 Lower limit signal (RLS)
b14
Axis 4 Near-point dog signal (DOG)
b15
Axis 4 STOP signal (STOP)
LD77MS16
Buffer
Setting items
memory
b0
Axis 1 Upper limit signal (FLS)
Axis 1 Lower limit signal (RLS)
b1
b2
Axis 1 Near-point dog signal (DOG)
b3
Axis 1 STOP signal (STOP)
b4
Axis 2 Upper limit signal (FLS)
b5
Axis 2 Lower limit signal (RLS)
b6
Axis 2 Near-point dog signal (DOG)
b7
Axis 2 STOP signal (STOP)
5928
Axis 3 Upper limit signal (FLS)
b8
b9
Axis 3 Lower limit signal (RLS)
b10
Axis 3 Near-point dog signal (DOG)
b11
Axis 3 STOP signal (STOP)
b12
Axis 4 Upper limit signal (FLS)
b13
Axis 4 Lower limit signal (RLS)
b14
Axis 4 Near-point dog signal (DOG)
b15
Axis 4 STOP signal (STOP)
b0
Axis 5 Upper limit signal (FLS)
b1
Axis 5 Lower limit signal (RLS)
b2
Axis 5 Near-point dog signal (DOG)
b3
Axis 5 STOP signal (STOP)
b4
Axis 6 Upper limit signal (FLS)
b5
Axis 6 Lower limit signal (RLS)
b6
Axis 6 Near-point dog signal (DOG)
b7
Axis 6 STOP signal (STOP)
5929
b8
Axis 7 Upper limit signal (FLS)
b9
Axis 7 Lower limit signal (RLS)
b10
Axis 7 Near-point dog signal (DOG)
b11
Axis 7 STOP signal (STOP)
b12
Axis 8 Upper limit signal (FLS)
b13
Axis 8 Lower limit signal (RLS)
b14
Axis 8 Near-point dog signal (DOG)
b15
Axis 8 STOP signal (STOP)
Setting value
b4
b0
Default
Meaning
value
0
0
"
Pr.22
0
Input
0
signal logic
selection"
0
is negative
0
logic
0
0: OFF
1: ON
0
0
"
Pr.22
0
Input
signal logic
0
selection"
0
is positive
logic
0
0: ON
0
1: OFF
0
0
Default
Buffer
Meaning
Setting items
value
memory
0
b0
Axis 9 Upper limit signal (FLS)
0
Axis 9 Lower limit signal (RLS)
b1
0
b2
Axis 9 Near-point dog signal (DOG)
0
b3
Axis 9 STOP signal (STOP)
0
b4
Axis 10 Upper limit signal (FLS)
0
b5
Axis 10 Lower limit signal (RLS)
0
b6
Axis 10 Near-point dog signal (DOG)
0
b7
Axis 10 STOP signal (STOP)
5930
0
Axis 11 Upper limit signal (FLS)
b8
0
b9
Axis 11 Lower limit signal (RLS)
"
Pr.22
0
b10
Axis 11 Near-point dog signal (DOG)
Input
0
signal logic
b11
Axis 11 STOP signal (STOP)
selection"
0
b12
Axis 12 Upper limit signal (FLS)
is negative
0
b13
Axis 12 Lower limit signal (RLS)
logic
0: OFF
0
b14
Axis 12 Near-point dog signal (DOG)
1: ON
0
b15
Axis 12 STOP signal (STOP)
0
b0
Axis 13 Upper limit signal (FLS)
"
Pr.22
Input
0
b1
Axis 13 Lower limit signal (RLS)
signal logic
0
b2
Axis 13 Near-point dog signal (DOG)
selection"
0
b3
Axis 13 STOP signal (STOP)
is positive
logic
0
b4
Axis 14 Upper limit signal (FLS)
0: ON
0
b5
Axis 14 Lower limit signal (RLS)
1: OFF
0
b6
Axis 14 Near-point dog signal (DOG)
0
b7
Axis 14 STOP signal (STOP)
5931
0
b8
Axis 15 Upper limit signal (FLS)
0
b9
Axis 15 Lower limit signal (RLS)
0
b10
Axis 15 Near-point dog signal (DOG)
0
b11
Axis 15 STOP signal (STOP)
0
b12
Axis 16 Upper limit signal (FLS)
0
b13
Axis 16 Lower limit signal (RLS)
0
b14
Axis 16 Near-point dog signal (DOG)
0
b15
Axis 16 STOP signal (STOP)
5 - 163
Chapter 5 Data Used for Positioning Control
Buffer memory address
(common for all axes)
Default
value
LD77MS2
LD77MS4
Default
Meaning
value
0000H
0
0
0
0
0
0
0
0
0
0
"
Pr.22
0
Input
0
signal logic
selection"
0
is negative
0
logic
0: OFF
0
1: ON
0
0
"
Pr.22
Input
0
signal logic
0
selection"
0
is positive
logic
0
0: ON
0
1: OFF
0
0
0
0
0
0
0
0
0
0
LD77MS16
5928
to
1928
5931

Advertisement

Table of Contents
loading

This manual is also suitable for:

Melsec-l seriesMelsec-ld77ms4Melsec-ld77ms16

Table of Contents