Set with a decimal.
K
Setting
value
Set with a decimal.
Setting
K
value
The Simple Motion module resets the value to "0" automatically when the
continuous operation is interrupted.
Set with a decimal.
Setting value
K
The Simple Motion module resets the value to "0" automatically after the axis
error reset is completed. (Indicates that the axis error reset is completed.)
Set with a decimal.
Setting value
K 1
The Simple Motion module resets the value to "0" automatically after restart
acceptance is completed. (Indicates that the restart acceptance is completed.)
Setting value
Positioning data No.
: Positioning data No.
1 to 600
: Block start designation
7000 to7004
: Machine OPR
9001
: Fast-OPR
9002
: Current value changing
9003
: Simultaneous starting of multiple axes
9004
Positioning starting point No.
1 to 50
1
Error reset request
1: Axis error is reset.
Restart command
1: Restarts
5 - 167
Chapter 5 Data Used for Positioning Control
Buffer memory address
Default
value
LD77MS2
LD77MS4
0
1500+100n
0
1501+100n
0
1502+100n
0
1503+100n
LD77MS16
4300+100n
4301+100n
4302+100n
4303+100n
n: Axis No.-1