When the "JOG start signal" is turned ON while the test function of
GX Works2 is used
When the "JOG star signal" is turned ON while the test function is used, it will be
ignored and the inching operation will not be carried out.
[LD77MS4 operation example]
In test mode flag
Forward run JOG
start signal
[Y8, YA, YC, YE]
Fig. 11.15 Operation when the JOG start signal is turned ON while the test function is used
Inching operation not
possible because the test
function is being used.
ON
ON
OFF
11 - 23
Inching operation not
possible because this
is not the rising edge
of the JOG start signal
OFF
(Note): Refer to Section 3.3 for input/output signal of LD77MS16.
Chapter 11 Manual Control
Forward run inching
operation execution
t