Classification
Error
Error name
of errors
code
Interpolation mode
523
error
Control method setting
524
error
Positioning
operation
errors
525
Sub point setting error
526
End point setting error
Center point setting
527
error
Error
• For starting, a composite speed is
designated in the reference axis
parameter "Interpolation speed
designation method" using the speed
interpolation control or
4-axis linear interpolation control.
• For starting, a reference axis speed is
designated in the reference axis
parameter "Interpolation speed
designation method" using the circular
interpolation control.
• The control method setting value is
outside the setting range.
• The number of control axes or the axis to
be interpolated differs from the previous
data when continuous positioning control
or continuous path control is to be
exercised for continuously.
• The NOP instruction was set to the
control method of positioning data No.
600.
Either of the following applies in the circular
interpolation with sub points designated.
• Start point = sub point
• End point = sub point
• Start point, end point, and sub point are in
line with each other.
• Sub point address and center point
address are outside the range of
–2147483648 to 2147483647.
• Start point is equal to end point in the
circular interpolation with sub points
designated.
• End point address is outside the range of
–2147483648 to 2147483647 in the
circular interpolation with auxiliary point
designation and center point designation.
Circular interpolation with center point
designation applicable to one of the
followings.
• Start point = Center point
• End point = Center point
• Center point address is outside the range
of –2147483648 to 2147483647.
16 - 28
Chapter 16 Troubleshooting
Operation status at error occurrence
At start
: The system does not
operate.
During operation : The system stops with the
setting (deceleration
stop/sudden stop) of the
detailed parameter 2
Sudden stop selection
(stop group 3).
(Note that the deceleration
stop only occurs during the
manual pulse generator
operation.)
At start
: The system does not
operate.
During operation : The system stops
immediately.